User Manual Built In

6
MODEL SPECIFICATIONS
COUNTERTOP OVERHANG
The control panel is designed to sit fl ush against the enclosure front wall. If the non-combustible enclosure countertop extends beyond
the front wall, creating a countertop overhang, it must be cut fl ush with the front wall for the width of the control panel or a gap will be
created exposing the forward portions of the left and right side grill fi re walls. See illustrations above.
Important: FOR YOUR SAFETY, you must provide openings in the island enclosure for drainage, replacement air, and cross-
ventilation of any storage area exposed to possible leakage from gas connections, the unit, or propane bottles. See
the ENCLOSURE REQUIREMENTS section for details.
TOP VIEW
Countertop
Lower support
Countertop
overhang
Control panel
NON-COMBUSTIBLE
CABINET CUT-OUT
DIMENSIONS
Fig. 6-1
FRONT VIEW
B
C
D
See next page
for substrate
considerations
Countertop
overhang
X
TOP VIEW
SIDE VIEW
Countertop
overhang
(Control
panel)
(Countertop)
Y
1
/
4
"
Clearance
(Overhang)
X= D-B
÷
2
Y= Total
Countertop
Overhang
A
Control
panel
Check clearance for
control panel removal
REV 8 - 1405291355
L-C2-276
MODEL SPECIFICATIONS TABLE
Table 1
A430i A530i A540i A660i A790i
Main burner BTU
N/P orifi ce drill size
25,000 x 2
#42/#54
30,000 x 2
#40/#53
20,000 x 3
#44/#55
25,000 x 3
#42/#54
30,000 x 3
#38/#53
Backburner BTU
N/P orifi ce drill size
13,000
#52/#59
13,000
#52/#59
18,000
#49/#57
18,000
#49/#57
20,000
#44/#56
Infrared searing burner BTU
N/P orifi ce drill size
17,000
#49/#56
25,000
#45/#55
17,000
#49/#56
25,000
#45/#55
25,000
#45/#55
Optional Aurora insulating liner model # 23130-50 23125-50 23150-50 3176-50 3186-50
Power supply rating
120VAC / 0.5A / 60 Hz
Oven lights rating 12V / 10 watt halogen bulb
A Countertop to unit bottom cut-out* 12" 12" 12" 12" 12"
B Side to side non-combustible cut-out* 25-
1
/
2
" 25-
1
/
2
" 32" 32" 37-
3
/
4
"
C Front to back non-combustible cut-out*† 19-
1
/
2
" 23-
1
/
2
" 19-
1
/
2
" 23-
1
/
2
" 23-
1
/
2
"
D Control panel width non-combustible cut-out 27" 27" 33" 33" 38-
3
/
4
"
If equipped
*Note: If using an insulating liner, consult liner instructions for counter cut-out dimensions and installation.
Includes any substrate at front wall of enclosure (in the area the rear of the control panel is to sit fl ush against). See SUBSTRATE
section on next page.
Only applicable for non-combustible enclosures that have countertops with an overhang (see illustration and section below).