Note: When a propane cylinder is installed inside
of the enclosure, the guidelines found in the
ENCLOSURE REQUIREMENTS section
MUST be followed.
For household propane or natural gas units:
CAUTION: Use only C.S.A. listed stainless-steel fl ex
connectors within the enclosure.
WARNING
A rubber or plastic connector will rupture or leak,
resulting in an explosion or serious injury if used
inside the appliance enclosure.
a. Run the attached fl ex connector routed under the
left side of the grill out of the enclosure and to the
gas stub.
b. Turn OFF the gas supply at the source. Then
connect the
1
/
2
" pipe adapter fi tting supplied with
the stainless-steel fl ex connector to the gas-supply
stub. Use pipe joint compound that is resistant to all
gasses on the male pipe fi tting and tighten securely.
DO NOT use pipe joint compound to connect
are fi ttings.
d. Turn all burner control knobs to the OFF position.
Turn the gas supply on. Then carefully check all gas
connections for leaks with a brush and half-soap/
half-water solution before lighting. NEVER USE A
MATCH OR OPEN FLAME TO TEST FOR LEAKS.
e. Close the dedicated gas-supply shut-off valve, then
slide the grill into place. Do not to pinch, kink, or
damage the gas connector line.
f. Rotate the adjustable support screws to the left to
raise and to the right to lower the respective side
of the appliance grill. Use a
7
/
16
" open-end wrench
as needed.
Important: Do not extend the support screws so
far that any part of the hanger is raised
off the counter top.
COUNTER PREPARATION
Consult Table 1 for non-combustible enclosure cut-out
dimensions. A Robert H. Peterson insulating liner must
be used if the counter or any supporting construction is
combustible. Consult the instructions that come with the
liner for dimensions and additional installation information
before beginning the installation.
This outdoor built-in grill must be supported by the
stainless-steel hanger extending from the upper portion
of the grill. The hanger rests on the left, right, and back
of the countertop and on the two front structural supports
with attached adjustable screws located below the control
panel on the left and right sides (see Fig. 12-3).
The control panel is designed to sit fl ush against the
enclosure front wall (see Fig. 12-2). If the non-combustible
enclosure countertop extends beyond the front wall,
creating a countertop overhang (see Fig. 12-1), it must
be cut fl ush with the front wall for the width of the control
panel or a gap will be created exposing the forward
portions of the left and right side grill fi re walls. Reference
the MODEL SPECIFICATIONS section.
Note: It is not necessary to remove the control panel
or knobs to install this unit.
CONNECTING THE GAS SUPPLY
For propane cylinders:
For connecting a propane unit to a portable propane tank,
read the safety warnings and follow the instructions in the
section SAFE USE AND MAINTENANCE OF PROPANE
GAS CYLINDERS.
INSTALLING THE BUILT-IN UNIT
Fig. 12-4
Fig. 12-1
Fig. 12-2
GAP CREATED
IDEAL
Flush-mounted
control panel
Proposed cut-
out in overhang
Countertop Countertop
Overhang
control panel
stops here
REV 8 - 1405291355
L-C2-276
OFF
Dedicated manual shut-off valve
To gas
system
Cut-out
Countertop
Hanger
Flex
connector
Gas inlet pipe
Fig. 12-3
Adjustable
support
screw
Bottom
of control
panel
Bottom
of cut-out
opening