Instructions
5
REV 6 0906230824
L-C2-11109
c. Remove the burner cap, and where fi tted,
the venturi tube from the center of the
burner (see Fig. 3-1 & Fig. 3-2).
d. If connected, disconnect the fl ex connector
from the double sideburner manifold. This
will enable you to lift out the unit from its
enclosure, giving ease of access.
e. Insert the socket into the center of the
burner, unscrew and extract the orifi ce,
taking care not to drop it from inside the
socket.
Check the number on the side or face of the new
orifi ce to be certain you are correctly converting for
your gas type (see step 1, above, for orifi ce sizes).
f. Replace with the new (correct) orifi ce for
your gas type.
g. Replace the unit into the enclosure or shelf
and follow steps a-c in reverse.
h. Re secure the battery into the battery
bracket. Replace the face and control knob.
Important: If converting the gas type, see the
CHECKING AND CONVERTING
THE REGULATOR section.
23 3/4"
12"
12 3/8"
2"
2"
1"
X
HEIGHT
4"
WIDTH
GAS SUPPLY PLUMBING REQUIREMENTS:
The gas supply pipe connection is to be made
through the fl oor at the rear of the enclosure.
Install the gas line stub at least 2" away from the
side walls and 1" from the back wall, but within 5"
of the back wall, as illustrated by the shaded area
X in Fig. 5-1.
CAUTION: An external valve (with a removable
key) in the gas line is advised for
safety and convenience, particularly
if the unit is accessible to children.
GAS SUPPLY AND MANIFOLD PRESSURES:
For natural gas - normal 7" water column (w.c.),
minimum 3-1/2", maximum 10-1/2". For propane
gas - normal 11" w.c., minimum 8", maximum 13".
PREPARING FOR INSTALLATION (Cont.)
INSTALLATION
A REGULATOR MUST BE PROVIDED AT THE
BOTTLE OR GAS SOURCE FOR USE WITH
PROPANE GAS.
Your double sideburner has been pre-assembled
at the factory.
1. CHECKING FUEL AND PROPER
ORIFICES: Fire Magic units are equipped
with orifi ces for natural gas, unless otherwise
indicated. For use with propane gas, smaller
orifi ces must be installed to avoid hazardous
overheating. (Please refer to Table 1 for the
correct orifi ce size.)
To change or inspect an orifi ce, you need a 5/16"
socket with a spacer (a small piece of tape balled
up, with the sticky side out, works well to hold
the orifi ce) to prevent the orifi ce from sliding too
far into, or dropping out of, the socket. The entire
sideburner should be lifted from its enclosure and,
where possible, tilted on its side while the orifi ce is
still installed. Complete the following steps:
a. Remove sideburner lid and lift off cooking
grid.
b. Removing the control knob and face screws
fi rst, carefully lift away the face.
Important: Prior to removing the face, you must
slide the battery out of the battery
bracket located on the right side of
the face.
Fig. 5-1
12"
Height
22 1/2"
11 1/2"
Width
1. CHECKING FUEL AND PROPER ORIFICES
Fire Magic units are equipped with orifi ces for
natural gas, unless otherwise indicated. For
use with propane gas, smaller orifi ces must be
installed to avoid hazardous overheating. Please
refer to Table 1 for the correct orifi ce size. Check
the orifi ce size by following the instructions
below. The drill size is stamped on the orifi ce.
If the number is not visible you may have to
remove the orifi ce (as detailed below) to read
the number stamped on the side of the orifi ce.
IF YOU ARE NOT SURE YOU HAVE THE
CORRECT SIDEBURNER ORIFICE SIZE (OR
WISH TO CHANGE THE ORIFICE), FOLLOW THE
STEPS BELOW.
CAUTION: IF THE BURNER HAS BEEN IN USE,
WAIT UNTIL THE BURNER AND ITS
COMPONENTS ARE COOL TO THE
TOUCH.
a. Remove sideburner lid and lift off cooking
grid.
b. Remove the control knobs and screws fi rst,
then carefully lift away the control panel.
Important: Prior to fully removing the
control panel, you must
disconnect the battery holder
assembly wires that are
located behind the control
panel.
c. Reach up under the burner support and
remove the burner retaining clip (see Fig.
5-1), located at the rear of the burner pipe.
d. Remove the burner cap and carefully lift
the burner up and out, clearing the ceramic
electrode (see Fig. 5-2), and pulling the
burner tube away from the orifi ce, located
on the end of the orifi ce holder on the left
side of the unit (see Fig. 5-3).
Note: You do not have to lift the burner
completely out of the unit to access the
orifi ce.
e. Using a
3
/
8
" socket, remove orifi ce from the
orifi ce holder (see Fig. 5-3) and check the
number stamped on the orifi ce face.
Fig. 5-2
Fig. 5-1
Fig. 5-3
Orifi ce located at
end of orifi ce holder
Orifi ce holder