Fire Magic Dimensions

GRILL CUT-OUT DIMENSIONS w/ INSULATING LINER
MODEL
OPENING REQUIRED
WIDTH DEPTH HEIGHT
A B C
Echelon E1060i
55” 26” 12”
Echelon E790i
42
1
/
8
26” 12”
Echelon E660i
36
3
/
8
26” 12”
Aurora A790i
42
1
/
8
26” 12”
Aurora A660i
36
3
/
8
26” 12”
Aurora A540i
36 5/
8
22
1
/
8
12”
Aurora A530i
30
1
/
8
26” 12”
Aurora A430i
30
1
/
8
22
1
/
8
12”
®
BUIL D IN G IN A C O M BUST IBL E IS L A N D
Notes:
1. A nominal 1/16” gap around the back and sides of the liner is recommended for ease of installation.
2. The countertop material may be placed up to the insulating liner on the back and sides.
3. A minimum of 100 sq. in. in air ventilation is required at cabinet face.
4. Cabinet face may be made of combustible material up to the front flange of the insulating liner.
To install and operate the Fire Magic outdoor gas appliance, please
refer to the Installation and Operating instructions and safety precautions
shipped with the appliance.
B
A
C
The information provided is for reference only. Detailed instructions are supplied with the insulation liner, unique to
the model selected. Read those instructions carefully and completely before starting installation of the liner.
6
INSULATING LINER MUST BE USED WHEN INSTALLING IN A COMBUSTIBLE ISLAND
Not used on Double Sideburner (3281), Single Sideburner (3279-1) or Drop-In Sideburner (3280)
Maintain proper clearance to combustible materials.
ACCESSORY & LEGACY CUT-OUT
DIMENSIONS w/ INSULATING LINER
MODEL
OPENING REQUIRED
WIDTH DEPTH HEIGHT
A B C
Deluxe
28 19
3
/
8
12
1
/
4
Power Burner
22
5
/
8
20
3
/
4
12”
Searing Station
18 3/8” 24
3
/
4
11 5/8”
B
A
C
GREEN: Support Hangers
RED: Heat Shield
BLUE: Combustible Material