7. Connect the hose and regulator to the cylinder. The propane gas and
cylinder are sold separately. Use a standard 20 lb. propane cylinder only.
Use this fire pit only with a propane vapor withdrawal supply system. See
Chapter 5 of the standard for storage and handling of liquefied petroleum
gas, ANSI/NFPA 58. Your local library or fire department should have this
book.
Storage of an appliance indoors is permissible only if the cylinder is
disconnected and removed from the appliance. A cylinder must be stored
outdoors in a well-ventilated area out of reach of children. A disconnected
cylinder must have dust caps tightly installed and must not be stored in a
building, garage or any other enclosed area.
The maximum inlet gas supply pressure: 250 psi. The minimum inlet gas
supply pressure: 5 psi. The minimum hourly of 10000 Btu is required input
rating for a fire pit for automatic operation at rating less than full input rating.
The pressure regulator and hose assembly supplied with the appliance must be used.
The installation must conform with local codes, or in the absence of local
codes, with national fuel gas code, ANSI Z223.1/NFPA54, natural gas and
propane Installation Code, CSA B149.1, or propane storage and handling
code, B149.2.
Use the LPG Tank Cover (U) to cover the LPG tank prior to placing
the LPG tank under the assembled Fire Pit
ASSEMBLY