User manual
REV 2 - 1511090915
L-C2-387
7
SPECIFICATIONS AND DIMENSIONS (cont.)
The following are the minimum tools required for the installation of your vent hood components. Additional tools
may be required for your individual installation.
TOOLS REQUIRED
WIRING DIAGRAM
Power cord
Wire harness,
main vent hood
3-position
rotary switch
Light
switch
Fan
switch
Light assembly
120V 50 Watt
Halogen bulbs
Thermostat snap
disc assembly
Blower motor
1200 CFM total
Wire harness,
blower vent hood
Table 2 - technical data
Specifi cation Value
Input electrical requirements
120VAC / 15 AMP minimum / 60 Hz / GFCI outlet
Fans 120 volts, 1200 CFM High Pressure Output
Power consumption 1,010 watts
Halogen lights rating 120V / 50 watt halogen light bulb
Vent Hood Model Designed For Use With Grills:
36-VH series up to (A,C)540
42-VH series up to (A,E)660
48-VH series up to (A,E)790
60-VH series up to E1060
The unit serial identifi cation number and rating label is located on the inside of the hood near
the control knobs. To view, the grease fi lter on the far right of the unit must be removed.
• 2 installers recommended
• Proper personal safety equipment
• Appropriate tools for electrical install
• Power drill
• Drill bit - Phillips head
• Medium Phillips screwdriver
• 3
/
8
" nut driver
• 1
/
4
" nut driver or
1
/
4
" hex driver (drill bit)
• Measuring tape
• Level
• Duct tape
• 100% Silicone sealant