COOKER HOOD FCA 550 INSTRUCTION BOOKLET GB
Contenents 1 -GENERAL INFORMATION ............................................................................................................................. 4 2 -SAFETY WARNINGS ...................................................................................................................................... 4 3 - INSTALLATION .............................................................................................................................................. 4 3.
Part 1 - INSTALLATION INSTRUCTIONS 1 - GENERAL INFORMATION This canopy hood is designed to be fitted into cabinets or chimney cooker hoods, placed above a hotplate. It can be used either in the extraction mode (ducted to the outside) or in the recirculation mode (internal recycling). Before starting the installation, consideration should be given to the difficulties to be found during installation.
Part 1 - INSTALLATION INSTRUCTIONS 3.1 - Installation of the fitted group 1 - Make a rectangular opening in the base of the overhead cupboard or hood, leaving a minimum of 13 mm from the outer edges according to the dimensions indicated in the table. 2 - Drill a hole into the upper side of the cabinet in accordance with the dimensions of the duct used for both the evacuation and recirculation mode.
Part 1 - INSTALLATION INSTRUCTIONS 4 - Close the ducting support by pushing and connecting the two pommels A (fig. 3). 3.2 - Ducting or recirculation fitting 1 - Ducting fitting: a) The hood can be ducted to the outside using either a rigid or a flexible Ø 100 or 120 mm duct to be fixed with suitable clamps, not provided (fig. 4). b) If the hood is provided with the charcoal filters fitted, the filters should be removed (see par.3.2 part 2).
Part 2 - USE AND MAINTENANCE INSTRUCTIONS 1 - SAFETY WARNINGS 1.1 1.2 1.3 1.4 It is most important that all the warnings shown in paragraph 2 of the Installation Instructions are strictly observed.
Part 2 - USE AND MAINTENANCE INSTRUCTIONS 3.1 - Synthetic filters 1 - This filter cannot be washed and should be replaced every two months. If the filter is provid ed with a saturation indicator, replace when the violet color of the dots which are visible from the outside is spread over the whole surface of the filter. 2 - Replacement: a) Remove the ducting grill, referring to paragraph 3.1.3. on installation. b) After having taken off the ducting grill, remove the filter stops (1).
Part 2 - USE AND MAINTENANCE INSTRUCTIONS 3.4 - Cleaning When cleaning the hood: - Never use a wet cloth or sponge, or running water. - Never use thinners or products containing alcohol, as they might damage the paintwork. - Never use abrasive cleaning materials, in particular when cleaning stainless steel surfaces. It is recommended to use a damp cloth and mild liquid household cleaner.
SERVICE AND SPARE PARTS In the event of your appliance requiring service, or if you wish to purchase spare parts, please contact your local Service Force Centre by telephoning:- 08705 929929 Your telephone call will be automatically routed to the Service Force Centre covering your post code area. For the address of your local Service Force Centre and further information about Service Force, please visit the website at www.serviceforce.co.
GUARANTEE CONDITIONS Standard guarantee conditions We, EHP, undertake that if within 12 months of the date of purchase this Firenzi appliance or any part thereof is proved to be defective by reason only of faulty workmanship or materials, we will, at our option repair or replace the same FREE OF CHARGE for labour, materials or carriage on condition that: ■ The appliance has been correctly installed and used only on the electricity supply stated on the rating plate.
This appliance conforms to European Low Voltage Directive 73/23/CEE governing electrical safety, European Directive 89/ 336/CEE on Electromagnetic Compatibility and Directive 93/68/CEE regarding CE Marking.