IPI Fireplace Owner's Manual

12 Maintenance
© Travis Industries 4081205 100-01211_000
Accent Light Replacement
Two accent lights are included in your fireplace to provide additional lighting. These bulbs will burn out
over time. To replace, follow the directions below:
Shut off gas to the fireplace and let it cool for 15 minutes.
Remove the glass (see page 15) and logs (see page 17).
Replace the halogen bulbs with the following bulbs:
(NOTE
: .Take care to not touch the bulb with your fingers – use foam packing or paper towel to hold the bulb):
35 Watt 120 Volt T4 Halogen Bulb (G6.35 Base)
Yearly Service Procedure
Failure to inspect and maintain the fireplace may lead to improper combustion and a potentially dangerous
situation. We recommend the following procedures be done by a qualified technician.
1. Turn the pilot flame to continuous. It should touch approximately 3/8" of the top of the flame sensor. If it does
not, contact your dealer for service.
2. Shut off gas to the fireplace and let it cool for 15 minutes. Remove the glass (see page 15).
3. Remove the log set (NOTE: the logs are very fragile - see page 17). If severely deteriorated, replace. Check
the logs for sooting. A small amount of soot along the bottom of the logs is normal. If excessive sooting is found,
the fireplace will require adjustment. Contact your dealer.
4. Inspect the burner and remove any debris.
Make sure the burner is not warped, cracked, or damaged.
Check the firebox and area around the pilot to make sure there is no warping or damage.
If any problem is found, discontinue use and contact your dealer for service.
5. Replace the log set. Clean and replace the glass (see
Glass Cleaning on page 24). If the glass is damaged,
replace. Make sure the gasket along the perimeter of the glass contacts the face of the firebox and forms an air-
tight seal. If it does not, re-align or replace the gasket to insure an air-tight seal.
6. Inspect the area behind the access door. Clean if necessary. Check the gas control valve and the gas lines. If
damage is found, discontinue use and contact your dealer for service. Clean the air channels, ducts, and blower
(if applicable).
7. Start the main burner. After 15 minutes the flames should be orange/yellow and not touch the top of the firebox.
If the pilot or main burners do not burn correctly, contact your dealer for service. Monitor blower operation.
8. Remove any debris or vegetation near the vent termination. Contact your dealer if any sooting or deterioration is
found near the vent termination.