Use and Care Manual

THE BATTERY DOOR WILL NOT CLOSE, THE AC QUICK CON-
NECTOR WILL NOT ATTACH TO THE ALARM, AND THE
ALARM WILL NOT ATTACH TO THE TRIM RING (SEE SECTION
6, FIGURE 9).
MOUNTING INSTRUCTIONS
CAUTION: THIS UNIT IS SEALED. THE COVER IS NOT REMOV-
ABLE!
1. Remove the trim ring from the back of the alarm by holding the
trim ring and twisting the alarm in the direction indicated by
the “OFF” arrow on the alarm cover.
2. After selecting the proper smoke alarm location as described in
section 1 and wiring the AC QUICK CONNECT harness as
described in the WIRING INSTRUCTIONS, attach the trim ring to
the electrical box (see figure 5).
3. Use a screwdriver to punch out only the pair of holes in the trim
ring that match your type of electrical box or plaster ring.
Mount the trim ring to the electrical box, using the appropriate
holes. NOTE: Use the circle, square and octagon markings near
each mounting hole in the trim ring to help you select the cor-
rect mounting holes (see figure 5).
4. Pull the AC QUICK CONNECTOR through the center hole in the
trim ring and mount the ring, making sure that the mounting
screws are positioned in the small ends of the keyholes before
tightening the screws (see figure 5).
5. Plug the AC QUICK CONNECTOR into the back of the alarm
(see figure 6), making sure that the locks on the connector snap
into place. Then push the excess wire back into the electrical
box through the hole in the center of the trim ring.
6. If you have finished all the WIRING, BATTERY INSTALLATION
AND TRIM RING MOUNTING STEPS, you can install the alarm
on the trim ring. Alignment marks are provided on the side of
the alarm and on the trim ring (see figure 7).
7. Install the alarm on the trim ring with the indicating marks
aligned and rotate the alarm in the direction of the “ON” arrow
on the cover until the alarm snaps in place (see figure 7).
8. Turn on the AC power. The green AC Power On Indicator
should be lit when the alarm is operating from AC power.