SMOKE/CARBON MONOXIDE ALARM Manual FADCQ

Understanding the Alarm LEDs and Horn Patterns
CONDITION HORN LEDs SMART BUTTON KEY
AC power is present Green light ON
Standby condition Red and Blue blink Quick push activates False Alarm Control
TM
once per minute and a longer press also activates a local
Push-to-Test sequence.
Standby condition Red and Blue blink Press and hold until the double chirp to
once per minute activate a local Push-to-Test sequence and
send a signal to other interconnected alarms.
Low-battery #1 Horn beeps once Yellow light flashes 5 Quick press will eliminate the low-battery
per minute times per minute after signal for about 8 hours.
horn beeps
Low-battery #2 Horn beeps once Yellow light flashes 7 Smart button inoperable.
per minute times per minute after Replace battery immediately.
horn beeps
Fault condition Horn beeps 2 times Yellow light flashes 2 Press and hold to check the alarm again.
per minute times per minute after Replace alarm if it remains in fault
horn beeps condition.
Local smoke Horn sounds 3 long Red-Yellow-Orange Quick press activates False Alarm
is detected tones, then pauses, lights flash with horn Control
TM
.
every 4 seconds
Local smoke condition Red light flashes 3 Quick press releases the latched LED.
is latched times every 10 seconds
Quick Quiet™ False Red light flashes 1
Alarm Control™ time every 10 seconds
is activated
Local CO is detected Horn sounds 4 short Blue light flashes 4 Quick press activates CO Reset.
tone pattern every times right after horn
5 seconds
Local CO condition Blue light flashes 4 Quick press erases the CO memory signal.
is memorized times every 10 seconds
CO Reset is activated Blue light flashes 1
time every 10 seconds
Remote signal is Horn sounds 3 long Quick press activates Smart Quiet™ Trigger
received from another tones, then pauses, Alarm Locator for smoke and heat alarms.
smoke or heat alarm every 4 seconds
Remote signal is Horn sounds 4 short
Quick press activates Smart Quiet™ Trigger
received from another tone pattern every Alarm Locator for other Model FADCQ
CO alarm 5 seconds combination smoke-CO alarms.
17