FIREYE PRIMELINE PRODUCTS • 25
Part Number Control
PPC4000 Stand-alone parallel positioning controller, with up to ten (10) selectable function
Modbus servo-motor outputs. User interface ordered separately.
NXCESVFD Plug-in assembly provides variable frequency (VFD/VSD) capability
60-2926 Enclosure, 12.5” x 10.5” x 6.5”, UL listed, fitted for PPC4000
129-190 Kit, fan replacement
User Interface for PPC4000
NXD410 User Interface with keypad, 24 VDC operation, 4 line back lit LCD display, panel mount only,
includes mounting brackets.
59-562-2 Cable assembly, 10 feet length, for interfacing NXD410 to PPC4000
Servos for PPC4000
FX04 Servo motor, 24 VDC operation, 4Nm, 3 lb.-ft. torque, without connectors, accepts 1/2 inch
NPT fitting, minimum travel time of 30 seconds for 90°
FX04-1 Servo motor, 24 VDC operation, 4Nm, 3 lb.-ft. torque, with connectors, minimum travel time
of 30 seconds for 90°
FX20 Servo motor, 24 VDC operation, 20Nm, 15 lb.-ft. torque, without connectors, accepts
1/2 inch NPT fitting, minimum travel time of 30 seconds for 90°
FX20-1 Servo motor, 24 VDC operation, 20Nm, 15 lb.-ft. torque, with connectors, minimum travel
time of 30 seconds for 90°
FX50 Servo motor, 24 VDC operation, 50Nm, 37 lb.-ft. torque, without connectors, accepts
1/2 inch NPT fitting, minimum travel time of 30 seconds for 90°
FX50-1 Servo motor, 24 VDC operation, 50Nm, 37 lb.-ft. torque, with connectors, minimum travel
time of 30 seconds for 90°
Servo Cables for PPC4000
59-565-6 Cordset, 6 feet, 1/2” NPT connectors on both ends, PVC jacket, temperature rating -40°C to
105°C, meets NEMA 1,3,4,6P and IEC67
59-565-40 Cordset, 40 feet, 1/2” NPT connectors on both ends, PVC jacket, temperature rating -40°C to
105°C, meets NEMA 1,3,4,6P and IEC67
Connector Kit for PPC4000
129-192 Connector, field wireable. Used for FX04-1, FX20-1, FX50-1 servos with connectors. Use
cable 59-565
59-565 Cable, 1 twisted pair, 2 power wires, suitable for servo hookup
O2 Probe for PPC4000
NXCES02-8 O2 probe assembly, 8” insertion
NXCES02-16 O2 probe assembly, 16” insertion
NXCES02-30 O2 probe assembly, 30” insertion
NXCES02P42, -1 Cartridge, probe replacement (model -1 for engineering code 00 only)
35-381-2 Flange, O2 probe mounting
129-189 Cover, mounting flange
Pressure Transducers for PPC4000
BLPS-15, -25, -30 Pressure transducer, 0 to15 psi (0 to 1030 mb), -14.7 to 25 psi (-1013 to 1720 mb), 0 to 30
psi (0 to 2070 mb), 4-20 mA output linear with pressure. ¼” NPTF mounting. Screw termi-
nal connections and conduit adapter cover.
BLPS-200 Pressure transducer, 0 to 200psi (0 to 13.8 Bar), 4-20 mA output linear with pressure. ¼”
NPTF mounting. Screw terminal connections and conduit adapter cover.
BLPS-300 Pressure transducer, 0 to 300 psi (0 to 20.7 Bar), 4-20 mA output linear with pressure. ¼”
NPTF mounting. Screw terminal connections and conduit adapter cover.
Temperature Transducers for PPC4000
TS350-2, -4, -8 Temperature sensor, Range 32°F to 350°F (0°C to 176°C), 4-20 mA output, linear with
temperature. Insertion length is 2, 4, 8 inches. Stainless steel thermowell included.
TS752-2, -4, -8 Temperature sensor, Range 32°F to 752°F (0°C to 400°C), 4-20 mA output, linear with