STARTING THE ENGINE
5. OPERATING PROCEDURES
(a) Make sure the AC circuit breaker is in
the OFF position. The generator may be
difficult to start if a load is connected.
(b) Open the fuel switch.
(c)Set the choke lever to the "START
(arrow mark)position.
Not necessary if the engine is warm.
Page 16
(d) Turn the engine switch to the
START position and hold it there for
4-5 seconds or until the engine starts.
START
ON
OFF
(e) After the engine started, return
the choke lever gradually to "RUN
position.
(f) Warm up the engine without load
for a few minutes.
RUN