User's Manual

FB155BC Version 2.0.0
- 9 -
3 CURRENT CONSUMPTION
Current Consumption (mA)
Status
MAX MIN AVG
Standby 3 0 1
Inquiry scan & Page scan (Slave) 48 0 22
Page scan (Slave) 12 0 1
Inquiry (Master) 45 39 42
Slave 24 18 21
Connected
Master 9 0 4
Slave 30 24 28
Data Transmission
Master 27 18 21
Slave 33 21 26
Data Reception
Master 33 21 27
Slave 33 27 29
Data Transmission/Reception
Master 33 21 28
Slave 6 0 1
Power save
Master 9 0 2
<Table 3-1 CURRENT CONSUMPTION>
- TEST CONDITIONS
Baud Rate : 9600 bps, Input Voltage : DC 5V
The power consumption will change depending on transmission speed and volume of data.