User's Manual

FZ200BS Manual VERSION 0.1.0
29
(1) Coordinator to set up the device's power is ON. After running
HyperTerminal, FZ200BS will reset.
The Zigbee Network is configured by Coordinator.
(2) Router to set up the device's power is ON. After running
HyperTerminal, FZ200BS will reset.
The Device participates in the Zigbee Network.
Its target device is automatically set.
A message “TARGET OK” is output.
If, “TARGET NON” or “TARGET ERROR” is output, its target device is not set.
Do the “9-4-2.Target device set-up”, again.
(3) Input “1234567890” into Hyper terminal(Router) and press “Enter(0x0D)” key.
FZ200BS transmits data (1234567890) inputted, Carriage Return(0x0D), and Line Feed(0x0A) at the
same time. (Do not input 0x0A. 0x0A is automatically added by FZ200BS.)
(4) Serial Data“1234567890” is output.(Coordinator)
Input Serial data of Serial port of FZ200BS.
After inputting the serial data, press “Enter” key.
53 bit including “Enter” key is a maximum length of Serial data can be transmitted by FZ200BS.
The Serial data sent from a Device is output through Serial port of its target device.
To transmit the other forms of data after Serial data transmission, you should wait until you get the
Serial Data’s result value. In other words, the other data transmission becomes possible after OK LED or