Product Manual
General information / safety instructions
18 firstAir screw compressor FAS03 – 37
The owner must ensure that the appropriate media connections
are provided.
The owner must ensure that the supply of the required quantity of
cooling medium (air/water) is guaranteed.
The owner must make sure that the required heat extraction is
guaranteed.
3.5 Description of the installed safety devices
Main switch with emergency stop
function
Fig. 1: Main switch
The main switch is also designed as an emergency stop switch. By
turning the main switch to the “0” position, the machine is stopped
by switching off the power immediately, thereby triggering an emer-
gency stop.
WARNING!
Danger to life due to restarting in an uncontrolled
manner!
Restarting the machine in an uncontrolled manner
can cause serious or fatal injuries.
- Before restarting, ensure that the reason for the
emergency stop has been rectified and that all
safety devices are installed and in working order.
- Only turn the main switch to the “l” position when
there is no more danger.
Emergency stop button
Fig. 2: Emergency stop button
Pressing the emergency stop button stops the machine by switching
off the power supply with immediate effect. After an emergency stop
button has been pressed, it must be unlocked by turning it to allow a
restart.
WARNING!
Danger to life due to restarting in an uncontrolled
manner!
Restarting the machine in an uncontrolled manner can
cause serious or fatal injuries.
- Before restarting, ensure that the reason for the
emergency stop has been rectified and that all
safety devices are installed and in working order.