Product Manual

Operation
54 firstAir screw compressor FAS03 37
Following rescue measures
9.
Inform the responsible authorities if the severity of the emer-
gency requires this.
10.
Assign specialist personnel to rectify the fault.
WARNING!
Risk of fatal injury if the machine is restarted
without authorisation or in an uncontrolled
manner!
An uncontrolled or unauthorised restart of the power
supply can result in severe or fatal injuries.
- Before restarting, ensure that all safety devices
have been fitted and are fully functional, and that
there are no hazards for personnel.
11.
Before restarting the machine, ensure that all safety equipment
is installed and functional.
11.3 Commissioning, starting and shutting down
11.3.1 Removing the transport protection
Remove the transport protection screw on the vibration damper plate on the base of the unit.
NOTE!
Damage to the compressor stage due to insufficient
lubrication!
If the unit is started up after a long transport route, 0.5 l of
Oil must be filled in the compressor stage straight away,
and the screw compressor must be rotated several times by
hand to ensure it does not start up without lubrication.