Product Manual

Operating instructions
60 firstAir screw compressor FAS03 37
12 Instructions for operation
12.1 Control panel
12.2 Description of the individual buttons
1 START Starts and operates the screw compressor, as long as it is free of faults, and switches from
“Shutdown” to “Operation” mode.
2 STOP: Stops compressor operation.
3 SET Press this button after changing parameters to confirm the input data.
4 ARROW UP Press this button when changing data to increase the value. This button is also used as a
selection button when making menu selections.
5 ARROW DOWN Press this button when changing data to decrease the value. This button is also used as
a selection button when making menu selections.
6 SHIFT/ENTER This button is used as a shift button for data changes, and as an enter button when mak-
ing menu selections.
7 ESC This button is used to return to a higher-level menu when using the menu.
2
3
1
4
5
6
7