Product Manual
Operating instructions
64 firstAir screw compressor FAS03 – 37
If the password entered is correct, press “F” (6) to open the menu. “Controller”, “Time” and “Maintenance”
then appear on the screen. Press “ESC” (7) to return to page 1 for the compressor.
The current menu is marked at the right by “◆”. If the symbol “◆” displays the selected function, press “F” (6)
to open the operating screen. To change between parameters, press “ARROW UP” (4) or “ARROW DOWN”
(5). Press “ESC” (7) to return to the page to set the parameters.
12.5 Messages about operating, alarm and fault statuses
12.5.1 Operating status
No.
Status displayed
Description of the status
1
Compressor stopped
Normal stop, compressor can be started
2
Emergency stop of the
compressor
The emergency stop button was pressed
3
Compressor running
The compressor is running
4
Compressor pressurised
The compressor is pressurised normally
5
Compressor not pressurised
The compressor is not pressurised
6
Compressor – idle stop
Idling period elapsed, compressor was stopped
(normal stop)
7
Compressor
Stop delay
Compressor must depressurise
before it can be started
8
Delay –
main motor overload
The main motor is overloaded, the compressor can only be
started after a given delay
9
Contact manufacturer
Servicing or maintenance is required on the compressor
Entering a password
0000
Controller Maintenance
Time