12.5.2 Alarm due to minor faults
A minor fault is signalised in the status bar of the control panel. The compressor does not stop; you will,
however, be informed that a minor intervention is required.
No.
Alarm displayed
Description of the alarm
1
Replace air filter
The air filter service life has expired
replace air filter, reset compressor
2
Air filter blocked
Air filter blocked or defective
needs replacement
3
Replace Oil filter
The Oil filter service life has expired
replace Oil filter, reset compressor
4
Oil filter blocked
Oil filter blocked or defective
needs replacement
5
Replace Oil precipitator
The Oil precipitator service life has expired
replace Oil precipitator, reset compressor
6
Oil precipitator blocked
Oil precipitator blocked or defective; needs replacement
7
Replace lubricant
The lubricant service life has expired
replace lubricant, reset compressor
8
Alarm high
compressed air final
temperature
The compressed air final temperature is too high, check the cooling
system
9
Alarm ambient tem-
perature too low
The ambient temperature is too low
increase the ambient temperature
10
Alarm ambient tem-
perature too high
The ambient temperature is too high
decrease the ambient temperature
11
Motor bearing tempera-
ture too high
The temperature of the bearings in the main motor is too high
check motor bearing
12
Main motor current
too high
The current at the main motor is too high check the lubrication sys-
tem
13
Temperature
precipitator tank too
high
The temperature in the precipitator tank is too high
check the cooling and lubrication system