66 firstAir screw compressor FAS03 37
12.5.3 Alarm due to major faults
If a major fault occurs and the system cannot be restarted, the compressor stops. Rectify the problem and
restart the compressor. A major fault is displayed in the status line of the controller.
No.
Alarm displayed
Description of the alarm
1
Alarm High com-
pressed air final tempera-
ture
The compressed air final temperature is too high check the lubri-
cation system
2
Alarm high final pressure
The final pressure is too high check the safety valve
3
Temperature sensor
no signal
No temperature sensor signal check sensor and cable
4
Pressure transducer
no signal
No pressure transducer signal, check sensor and cable
5
Stop main motor over-
load
The main motor is overloaded, check the lubrication system for the
drive
6
Stop cooling air fan mo-
tor overload
The motor for the cooling air fan is overloaded
check the cooling air fan; if a thermal overload relay is installed, re-
set the relay
7
Stop water loss
(for water-cooled systems)
Cooling water could not be refilled
check the cooling water system
8
Phase sequence fault
Direction of drive rotation incorrect
change phase sequence of input current
9
Temperature too low
The lubricant temperature is too low
heat up the lubricant
10
Voltage too high
The supply voltage is too high
check the voltage supply
11
Voltage too low
The supply voltage is too low
check the voltage supply
12
Precipitator tank tempera-
ture too high
The temperature in the precipitator tank is too high
check the cooling system
13
Precipitator tank pressure
too high
The pressure in the precipitator tank is too high
check the relief valve
14
Current incorrect
The power supply fluctuates, pressure relief current too high
check the power supply and relief valve