User’s Manual Important! Please Read Carefully And Save This Document. This User’s Manual contains important information about your combination smoke and CO alarm’s operation. If you are installing this alarm for use by others, you must leave this manual (or a copy of it) with the end user. NOTE: See Safe & Sound ID and Pairing Code Label on back cover of User’s Manual.
User’s Manual Model: 1039102 Installed On Replace By 2
Table of Contents Welcome 4-5 Parts of This Alarm 5 Smoke & Carbon Monoxide Alarm 6 Where to Install 7-8 Where Not to Place Your Install 9 Set-Up and Installation 10 - 13 Installation of Adapter Plug 14 - 17 Wireless Interconnect 17 When the Alarm Sounds 18 Using the Silence Feature 19 Weekly Testing 20 Regular Maintenance 21 Alarm End of Life 21 Ionization and Photoelectric Technology 22 Fire Safety Tips
Welcome Welcome to your Onelink Safe & Sound alarm. Thank you for choosing Onelink by First Alert for your safety needs. In addition to the alarm sounds, you can receive notifications in case of an emergency to help provide a warning of a fire or carbon monoxide leak while you are home or away. Please take time to read this manual and make this alarm an integral part of your family’s safety plan. Visit www.firstalert.com/onelink for additional information.
System Requirements Wireless Network Android or iOS Device Onelink Home App For best results, it’s recommended to use a 2.4 GHz / 802.11 b/g/n router. You can use your Onelink Safe & Sound with Android 5 or later and with iOS 10 or later. Search and download Onelink Home app from the App Store or Google Play. Parts of this Alarm 8 9 1 6 2 4 5 11 7 10 3 1. Speaker 4. Hot (black) AC Wire 8. Mounting Bracket 2. Color Indicator Ring 5. Neutral (white) AC Wire 9. Mounting Slots 3.
Smoke & Carbon Monoxide Alarm LED Color Patterns Smoke / CO Events Voice Guide Power Up Power Up Programming, Silencing & Pairing “[Location, example: “Hallway”] Location saved.” Testing “The testing is complete.” Emergency [Test Complete - interchanging to next test/ Safe & Sound out of alarm mode] Welcome Hello and welcome to your Onelink Safe & Sound. Download the Onelink Home App through the App Store or Google Play. The app will walk you through the process.
Where to Install Minimum coverage for smoke alarms, as recommended by the National Fire Protection Association (NFPA), is one smoke alarm on every level, and in every bedroom (See “Regulatory Information For Smoke Alarms” for details on the NFPA recommendations). For CO alarms, the National Fire Protection Association (NFPA) recommends that CO alarms be installed on every level and in the central location outside each bedroom. For added protection, install additional CO alarms in every bedroom.
Where to Install (Continued) CEILING PLACE HERE *For ceiling installation only.
Where Not to Place Your Install Do Not Place Your Smoke & CO Alarm: • In garages, furnace rooms, crawl spaces and unfinished attics. Avoid extremely dusty, dirty or greasy areas. • Where combustion particles are produced. Combustion particles form when something burns. Areas to avoid include poorly ventilated kitchens, garages, and furnace rooms. Keep units at least 20 feet (6 meters) from the sources of combustion particles (stove, furnace, water heater, space heater) if possible.
~ Set-Up & Installation DANGER: ELECTRICAL SHOCK HAZARD. Turn off power to the area where you will install this unit at the circuit breaker or fuse box before beginning installation. Failure to turn off the power before installation may result in serious electrical shock, injury or death. Tools You Will Need: • Needle-nose pliers or utility knife • Standard phillips screwdriver • Wire strippers Ensure the Android software is updated to 5 or later and iOS software is updated to iOS 10.
Set-Up & Installation (Continued) 6 7 8 5 5 4 4 2 1 1 3 3 1. Smoke/CO Alarm 2. Ceiling 3. Power Connector 4. Wire Nut 5. Junction Box 6. Neutral Wire (white) 7. Interconnect Wire (orange) 8.
Set-Up & Installation (Continued) Interconnected Units Must Meet All of the Following Requirements: • A maximum of 18 compatible units may be interconnected (Maximum of 12 smoke alarms). • The same fuse or circuit breaker must power all interconnected units. • The total length of wire interconnecting the units should be less than 1000 feet (300 meters). This type of wire is commonly available at Hardware and Electrical Supply stores.
Set-Up & Installation (Continued) Step 4 Plug the power connector into the back of the alarm. Step 5 Position the base of the alarm over the mounting bracket, and turn the alarm clockwise (right) until unit is set in place. This activates the battery back-up. Removing the unit from the mounting bracket and disconnecting from AC power will power the unit off. NOTE: After you activate the alarm for the first time, the Color Indicator Ring will power up and the alarm will welcome you.
Installation of Adapter Plug Installation Instructions: Verify which models are installed in your system to determine the adapter plug to use. Step 1 ! IMPORTANT FEATURE: 1039102 is compatible with most First Alert and BRK hardwire alarm models. White Orange Plug Pin View Black Side View NOTE: Twist tie should not be removed.
Installation of Adapter Plug (Continued) WARNING: Installation of this unit must conform to the electrical codes in your area; Article ! 760 of NFPA 70 (NEC), NFPA 72, NFPA 101; SBC (SBCCI); UBC (ICBO); NBC (BOCA); OTFDC (CABO), and any other local or building codes that may apply. Wiring and installation must be performed by a licensed electrician. Failure to follow these guidelines may result in injury or property damage. This unit must be powered by a 24-hour, 120VAC pure sine wave 60Hz circuit.
~ Installation of Adapter Plug (Continued) DANGER: If any unit in the series does not alarm, TURN OFF POWER and recheck connections. RESTORE POWER. If any unit within interconnected alarms does not alarm, replace it immediately. 1 5 3 4 1. Mounting Bracket 2. First Alert® / BRK® Alarm 3. Kidde® Adapter 4. Firex® Adapter 5.
Installation of Adapter Plug (Continued) Interconnected Units Must Meet All of the Following Requirements: • A maximum of 18 compatible units may be interconnected (Maximum of 12 smoke alarms). • The same fuse or circuit breaker must power all interconnected units. • The total length of wire interconnecting the units should be less than 1000 feet (300 meters). The interconnect wire should be #18 gauge or larger, rated at least 300V.
When the Alarm Sounds What to Do If Your Smoke Alarm Sounds • If the unit alarms and you are not testing the unit, it is warning you of a potentially dangerous situation that requires your immediate attention. NEVER ignore any alarm. Ignoring the alarm may result in injury or death. • If the unit alarms get everyone out of the house immediately. What to Do in Case of a Fire • Don’t panic; stay calm. Follow your family escape plan. • Get out of the house as quickly as possible.
Using the Silence Feature The Silence Feature This feature is intended to temporarily silence the horn while you identify and correct the problem. Do not use the Silence Feature in emergency situations. It will not correct a CO problem or extinguish a fire. The Silence Feature can temporarily quiet an unwanted alarm for several minutes. You can silence this smoke/ CO alarm by pressing the Test/Silence button on the alarm cover for at least 3-5 seconds or via the Onelink Home App.
Weekly Testing ! WARNING: NEVER use an open flame of any kind to test this unit. You might accidentally damage or set fire to the unit or to your home. NEVER use vehicle exhaust! Exhaust may cause permanent damage and voids your warranty. ! WARNING: DO NOT stand close to the alarm when the horn is sounding. Exposure at close range may be harmful to your hearing. When testing, step away when horn starts sounding.
Regular Maintenance This unit has been designed to be as maintenance-free as possible, but there are a few simple things you must do to keep it working properly: • Test it at least once a week. • Clean the smoke/CO alarm at least once a month; gently vacuum the outside of the smoke/CO alarm using your household vacuum’s soft brush attachment. A can of clean compressed air (sold at computer or office supply stores) may also be used. Follow manufacturer instructions for use. Test the smoke/CO alarm.
Ionization & Photoelectric Technology This alarm uses photoelectric technology. All First Alert ® Onelink ® smoke alarms conform to regulatory requirements, including UL217 and are designed to detect particles of combustion. Smoke particles of varying number and size are produced in all fires.
Fire Safety Tips (Continued) Basic Safety Information Keep alarms clean, and test them weekly. Replace alarms immediately if they are not working properly. Smoke alarms that do not work cannot alert you to a fire. Keep at least one working fire extinguisher on every floor, and an additional one in the kitchen. Have fire escape ladders or other reliable means of escape from an upper floor in case stairs are blocked.
What You Need to Know About CO What is CO? Carbon Monoxide (CO) is an invisible, odorless, tasteless gas produced when fossil fuels do not burn completely, or are exposed to heat (usually fire). Electrical appliances typically do not produce CO. These Fuels Include: Wood, coal, charcoal, oil, natural gas, gasoline, kerosene, and propane. Common appliances are often sources of CO. If they are not properly maintained, are improperly ventilated, or malfunction, CO levels can rise quickly.
Potential Sources of CO in the Home Fuel-Burning Appliances: Like portable heater, gas or wood burning fireplace, gas kitchen range or cooktop, gas clothes dryer. Damaged or Insufficient Venting: Corroded or disconnected water heater vent pipe, leaking chimney pipe or flue, or cracked heat exchanger, blocked or clogged chimney opening. Improper Use of Appliance/Device: Operating a barbecue grill or vehicle in an enclosed area (like a garage or screened porch).
Potential Sources of CO in the Home (Continued) How Can I Protect My Family from CO Poisoning? A CO alarm is an excellent means of protection. It monitors the air and sounds a loud alarm before carbon monoxide levels become threatening for average, healthy adults. A CO alarm is not a substitute for proper maintenance of home appliances. To help prevent CO problems and reduce the risk of CO poisoning: 26 • Clean chimneys and flues yearly. Keep them free of debris, leaves, and nests for proper air flow.
Regulatory Information for CO Alarms What Levels of CO Cause an Alarm? Underwriters Laboratories Inc. Standard UL2034 requires residential CO alarms to sound when exposed to levels of CO and exposure times as described below. They are measured in parts per million (ppm) of CO over time (in minutes). UL2034 Required Alarm Points*: • If the alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN 4 & 15 MINUTES. • If the alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN 10 & 50 MINUTES.
Regulatory Information for Smoke Alarms Installing Smoke Alarms in Single-Family Residences NOTE: This information is specific to the smoke and carbon monoxide alarm and is not applicable to the home automation capability. The National Fire Protection Association (NFPA), recommends one smoke alarm on every level and in every bedroom. In new construction, the smoke alarms must be AC powered and interconnected. See “Recommended Placement” for details.
Regulatory Information Federal Communications Commission (FCC) Compliance Statement NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Modular Devices FCC and Compliance Statements OEM Responsibilities to Comply With FCC Regulations The A76F Module has been certified for integration into products only by OEM integrators under the following condition: 1. The transmitter module must not be co-located or operating in conjunction with any other antenna or transmitter. As long as the condition above is met, further transmitter testing will not be required.
Special Compliance Considerations This smoke alarm is suitable for use in apartments, condominiums, townhouses, hospitals, day care facilities, health care facilities, boarding houses, group homes and dormitories provided a primary fire detection system already exists to meet fire detection requirements in common areas like lobbies, hallways, or porches. Using this smoke alarm in common areas may not provide sufficient warning to all residents or meet local fire protection ordinances/regulations.
General Limitations for Smoke/CO Alarms (Continued) Smoke/CO Alarms Cannot Work Without Power. Battery operated units cannot work if the batteries are missing, disconnected or dead, if the wrong type of batteries are used, or if the batteries are not installed correctly. If the AC power is cut off for any reason (open fuse or circuit breaker, failure along a power line or at a power station, electrical fire that burns the electrical wires, etc.).
Troubleshooting Guide App FAQ If the App... Problem... You Should... Is unable to be downloaded or installed. You cannot download or install the app. Contact Customer Service Team Alarm FAQ If the Alarm... Problem... You Should... Light flashes yellow and Horn sounds three “chirps” every minute. Voice: “Detector error. Please see manual or call customer service” every 5 hours. Malfunction Signal. Device is not working properly and needs to be replaced.
Limited Warranty BRK Brands, Inc., (“BRK”) the maker of First Alert® brand products warrants that for a period of three years from the date of purchase, this product will be free from defects in material and workmanship. BRK, at its option, will repair or replace this product or any component of the product found to be defective during the warranty period. Replacement will be made with a new or re-manufactured product or component.
Copyright and Technical Specifications ©2018 BRK Brands, Inc. All rights reserved. Distributed by BRK Brands, Inc., Aurora, Illinois 60504. BRK Brands, Inc. is a subsidiary of Newell Brands Inc. (NYSE:NWL). Printed in USA. Apple HomeKit Apple, iPhone, iPad, iPad Air, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. HomeKit is a trademark of Apple Inc. App Store is a service mark of Apple Inc.
©2018 BRK Brands, Inc. All rights reserved. • Distributed by BRK Brands, Inc. BRK Brands, Inc. is a subsidiary of Newell Brands Inc. (NYSE:NWL) 3901 Liberty Street Road, Aurora, IL 60504-8122 Customer Service Team: 1-(800) 323-9005. • www.firstalert.