User Guide

37
Event Logging Procedures
Event Logging ProceduresEvent Logging Procedures
Event Logging Procedures
About Event Logging
About Event LoggingAbout Event Logging
About Event Logging
The system records various events in a history log, which can be viewed by the master
user using an Alpha Display keypad.
The Event Log holds up to 100 (FA168CPS) or 50 (FA148CP) events.
Events are displayed in chronological order, from most recent to oldest.
When the log is full, the oldest event is replaced by the logging of any new event.
Viewing the Event Log
Viewing the Event LogViewing the Event Log
Viewing the Event Log
1. + [#] + 6 + 0
(Master Code)
Alpha Displays:
DISARMED
READY TO ARM
2. The system displays the most recent event as follows:
event number, type of event (see table of codes below),
zone or user number (depending on type of event)
partition in which event occurred, time and date of
the event’s occurrence.
3. Pressing [] displays previous events (back in time).
Pressing [#] displays events forward in time.
4. Exit by pressing any key other than [] or [#].
001 E441 U001 P1
12:34AM 01/02/00
Understanding the Type of Event Displayed
Understanding the Type of Event DisplayedUnderstanding the Type of Event Displayed
Understanding the Type of Event Displayed
If the event code is preceded by an E (as in the above display), it means that the
event is new and ongoing; if preceded by an R, it means the event has been restored.
See your installer for more detailed information regarding the meanings of these codes
Code - Definition Code - Definition Code - Definition Code - Definition
110 - Fire Alarm 301 - AC Power 380 - Global Trouble, Trouble
Day/Night
442 - Keyswitch Arm/Disarm STAY
121 - Duress 302 - Low System Battery/Batt
Test Fail
381 - RF Supervision Trouble 459 - Recent Closing
122 - Alarm, 24-hour Silent 305 - System Reset (Log only) 382 - Supervsn Aux Wire Zone 570 - Bypass
123 - Alarm, 24-hour Audible 321 - Bell/Siren Trouble 383 - RF Sensor Tamper 601 - Manual Triggered Dialer Test
131 - Alarm, Perimeter 333 - Trble, Exp. Mod. Supervsn 384 - RF Sensor Low-battery 602 - Periodic Test
132 - Alarm, Interior 341 - Trble, ECP Cover Tamper 393 - Clean Me 606 - AAV to Follow
134 - Alarm, Entry/Exit 344 - RF Receiver Jam 401 - Disarmed, Armed AWAY,
Armed STAY
607 - Walk Test Entered/Exited
135 - Alarm, Day/Night 351 - Telco Line Fault 403 - Sched. Arm/Disarm
AWAY
623 - Event Log 80% Full
143 - Alarm, Expansion Module 353 - Long Range Radio Trble 406 - Cancel by User 625 - Real-Time Clock was Changed
(log only)
145 - ECP Module cover tamper 373 - Fire Loop Trouble 407 - Remote Arm/Disarm 627 - Program Mode Entry (log
only)
146 - Silent Burglary 374 - Exit Error Alarm 408 - Quick Arm AWAY 628 - Program Mode Exit (log only)
150 - Alarm, 24-Hr Aux/Mon zn 409 - Keyswitch Arm/Disarm
AWAY
642 - Latch Key (log only)
162 - Carbon Monoxide 441 - Disarm/Arm/ Quick-Arm
STAY/INSTANT
750 -789 - Configurable Zone Type