Troubleshooting
Fault Probable Cause Solution
Water changes
color or becomes
cloudy.
Rower is in direct
sunlight or has not had
water treatment.
Change rower location to reduce
direct exposure to sunlight. Add water
treatment or change tank water as
directed in the water treatment section
of this manual. Consider using distilled
water to refill tank.
Rowing stroke
return is too light.
Bungee not under
enough tension.
Rowing Belt missing
one wrap around rower
belt pulley.
Bungee has slipped off
the Bungee Pulley
Wheel.
Cut Bungee Tie Rack and tighten slightly
on Bungee Hook.
Computer screen
illuminates, but
does not register
when rowing.
Loose or failed
connection/Sensor gap
too wide (see erratic
computer display).
Check that the computer lead is
connected properly. If connected
properly check sensor gap. Contact your
local service center if this fails to ad-
dress the problem.
Rowing Belt can’t
extend to the end
of rowing stroke
or no resistance.
Rowing Belt needs to
be unwrapped 1 turn
or, requires an extra
wrap on the Rower
Belt Pulley
The Rower
computer does
not illuminate
after battery
installation.
Batteries installed
incorrectly or need
replacing.
Reinstall batteries in correct position
and try again. If the LCD screen fails to
illuminate, try rotating the batteries
slightly in the computer. If this fails,
contact your local service center.
The Rower
computer display
is erratic while
displaying SPM
and 500meter
times.
Gap between sensor
and magnetic ring is
too wide.
Remove large service cover and check gap
between sensor and magnetic ring (should
be no more than 2.5mm).