User Manual

10 | T15
11
2. ATTACH HOPPER ELBOW - Seat the hopper
adapter against the marker and push the load
door retaining pin towards the back of the
marker so it holds the hopper elbow in place.
3. ROTATE BARREL - With the magazine removed
rotate the barrel by grabbing it at the end
between the muzzle brake and the gas block.
Look into the magazine well to confirm the
position of the ball port in the barrel.
DO NOT try to rotate the barrel by rotating
the hand guard or gas block. This will cause
damage to your marker.
1. REMOVE HOPPER COVER PLATE - Take the
hand guard off of the marker and use the
barrel nut tool to remove the barrel sleeve.
Once the barrel sleeve is removed, push
the load door retaining pin out towards the
front of the marker.
CLEANING
• Never perform maintenance on a loaded or pressurized T15 marker.
Remove all projectiles from the magazine and marker prior to doing any
cleaning or maintenance. Never use petroleum based cleaning solvents or lubricants.
• Do not use cleaning solvents that come in aerosol cans.
To clean the T15 marker, remove the barrel as described in the “Operational Instructions”.
Use a .68 caliber soft nylon brush or 12 gauge patch tip with a soft cotton cloth to clean the
barrel. Do not place lubricant or water in the barrel of the T15. It is designed to be used with
the barrel completely dry.
• Keep the barrel of the T15 dry.
• Wipe off any dirt or grime from the outside of the T15 with a dry cloth.
To clean the magazine, wind the ball pusher all the way back. The magazine is designed with
a spring retention sleeve that will keep the spring from binding when the the magazine is
taken apart.
OILING THE MARKER
IMPORTANT: Before performing any of the following instructions, remove magazine.
Point marker in safe direction and discharge until degassed.
FOR OPTIMUM PERFORMANCE, DO THE FOLLOWING MONTHLY:
Place 2 drops of NON-PETROLEUM BASED synthetic paintball marker oil into the ASA of the
marker before attaching an air source. When the marker gases up the air will blow the oil
through out the internals of the marker.
OPERATIONAL CONSIDERATIONS
• The operational temperature range for the T15 marker is 37° F to 120°F.
• The T15 is designed to operate on a minimum of 800psi of air pressure.
HOPPER ATTACHMENT T15 CLEANING & MAINTENANCE