Voyager 3000 Specifications
RAID level 0, 1, 3, 5 (or non-RAID disk spanning)
Failure management Bad sector reassignment, hot
swapping, spare drive operation,
background rebuilding
Host OS compatibility OS independent
Cache size Up to 32 MBytes
Host interface Single interface Ultra SCSI
Hard disk interface Fast Wide SCSI2/Ultra
Hard disk channels 2
Channel Terminator Active, software programmable
SCSI protocol SCSI-1, SCSI-2, Fast -2,Ultra SCSI
SCSI transfer rate 8-bit/Wide: 10/20/40 MBytes/sec
synchronous
8-bit/Wide: 5/10 MBytes/sec
asynchronous
Max. SCSI drives 6/13
No. of logical drives 8 with different RAID operation
Partitions 8 per logical drive
No. of LUNs 8 per channel
Control Front panel or via RS-232 terminal
SCSI connectors 8-Bit/Wide: 68-pin header (host side)
SCSI cabling Single-ended
Controller Voltage +5 Volts
Controller Current 1.5 Amp
Operating Temperature 5 to 40 °C
Non Operating Temp -40°C to +66°C (Transportation and
short term storage)
Relative Humidity 10-96%, non-condensing
Operating Altitude Sea level to 10,000 ft.
Weight Single tower (bays empty) 24.8 lbs/11.3Kgs
Twin tower (bays empty) 41.8lbs/19Kgs
Rack (bays empty) 13.2 lbs/6Kgs
Empty carrier 2.42lbs/1.1kgs
Height Single tower 20.24”/51.4cm
Twin tower 20.24”/51.4cm
Rack 5.2”/13.2cm
Width Single tower 8.66”/22.0cm
Twin tower 13.9”/35.3cm
Rack 18.9”/48.0cm
Depth Single tower 13.98”/35.5cm
Twin tower 13.98”/35.5cm
Rack 11.81”/30.0cm