Product Manual

Table Of Contents
General operation
Seite/Page 110 - Kaptitel/Chapter 12: General operation 13.4.17
Oil pressure status
Cylinder head temperature
Temperature of exhaust manifold
• Winding temperature
• Speed/RPM
Utilisation in percent
Fig. 12.3.2-1: Default display screen
Note:The Display shows the iControl board input voltage.
At generator systems with 12 V starter system these is equal
with the starter battery voltage.
At generator system with 24 V starter system the starter
battery voltage can not be displayed.
12.3.3 Operating modes
The Panda iControl2 controller offers different operating modes.
12.3.3.1 Stand-by mode
After the controller is switched on with the On/Off button, the system is in stand-by mode. This is indicated by the
output "STANDBY" in the status field in the top right corner of the default display screen. In this operating mode, the
system can be switched off with the On/Off button, and the generator can be started up with the Start/Stop button.
With the cursor buttons, the service information screen can be accessed.