Fig. 16.2.2-1: Warning and fault thresholds for different generator types
Generator type Warning/fault Warning threshold Fault threshold
5000i marine Cylinder head temperature
Delay
85 °C
5s
95 °C
5s
Winding temperature
Delay
130 °C
5s
135 °C
5s
Exhaust manifold temperature
Delay
70 °C
1s
75 °C
1s
5000i vehicle Cylinder head temperature
Delay
90 °C
5s
95 °C
5s
Winding temperature
Delay
130 °C
5s
135 °C
5s
Exhaust manifold temperature
Delay
100 °C
1s
105 °C
1s
P8000i / P10000i marine Cylinder head temperature
Delay
90 °C
5s
95 °C
5s
Winding temperature
Delay
130 °C
5s
135 °C
5s
Exhaust manifold temperature
Delay
70 °C
1s
75 °C
1s
P8000i / P10000i vehicle Cylinder head temperature
Delay
90 °C
5s
95 °C
5s
Winding temperature
Delay
130 °C
5s
135 °C
5s
Exhaust manifold temperature
Delay
100 °C
1s
105 °C
1s
P8-P50 marine Cylinder head temperature
Delay
90 °C
5s
95 °C
5s
Winding temperature
Delay
130 °C
5s
135 °C
5s
Exhaust manifold temperature
Delay
70 °C
1s
75 °C
1s
P8-P50 vehicle Cylinder head temperature
Delay
95 °C
5s
100 °C
5s
Winding temperature
Delay
160 °C
5s
165 °C
5s
Exhaust manifold temperature
Delay
100 °C
1s
105 °C
1s
P15000i marine Cylinder head temperature
Delay
90 °C
5s
95 °C
5s
Winding temperature
Delay
130 °C
5s
135 °C
5s
Exhaust manifold temperature
Delay
70 °C
2s
75 °C
2s
P15000i vehicle Cylinder head temperature
Delay
90 °C
5s
95 °C
5s
Winding temperature
Delay
130 °C
5s
135 °C
5s
Exhaust manifold temperature
Delay
95 °C
2s
100 °C
2s
All generator types Starter battery voltage low
Delay
11.8 V
30 s
10.8 V
30 s
Starter battery voltage high 15.0 V
5s
--
--