Product Manual
Table Of Contents
- Marine Generator Manual
- Current revision status
- 3. General Instructions and Regulations
- 3.1 Safety first!
- 3.2 Tools
- 3.3 Manufacturer declaration in accordance with the Machinery Directive 2006/42/EC
- 3.4 Customer registration and guarantee
- 3.5 Safety Instructions - Safety First!
- 3.5.1 Safe operation
- 3.5.2 Observe safety instructions!
- 3.5.3 Personal protective clothing (PPE)
- 3.5.4 Cleanliness ensures safety
- 3.5.5 Safe handling of fuels and lubricants
- 3.5.6 Exhaust fumes and fire protection
- 3.5.7 Safety precautions against burns and battery explosions
- 3.5.8 Protect your hands and body from rotating parts!
- 3.5.9 Anti-freeze and disposal of fluids
- 3.5.10 Implementation of safety inspections and maintenance
- 3.6 Warning and instruction signs
- 4. In case of Emergency First Aid / Im Notfall - Erste Hilfe
- 5. Basics
- 5.1 Intended use of the machine
- 5.2 Purpose of the manual and description of the definitions of the trained persons/operators/users
- 5.3 Components of the i-system
- 5.4 Panda transport box
- 5.5 Opening the GFK sound insulation capsule
- 5.6 Transport and loading/unloading
- 5.7 Special service instructions and measures for extended machine downtimes and decommissioning
- 6. Panda 5000i PMS generator
- 7. Installation Instructions
- 7.1 Personal requirements
- 7.2 Place of installation
- 7.3 Generator Connections
- 7.4 Installation of the cooling system - raw water
- 7.4.1 General information
- 7.4.2 Installation of the through hull fitting in Yachts - scheme
- 7.4.3 Quality of the raw water sucking in line
- 7.4.4 Generator installation above waterline
- 7.4.5 Generator installation below waterline
- 7.4.6 First filling and ventilation of the internal cooling water circuit
- 7.4.7 Temperature check for controlling the cooling water circuit
- 7.5 Installation of the water cooled exhaust system
- 7.6 .Installation of the waterlock
- 7.7 Exhaust / water separator
- 7.8 Installation exhaust water separator
- 7.9 Fuel system installation
- 7.10 Ventilating the fuel system
- 7.11 Generator DC system installation
- 7.12 Generator AC System Installation
- 7.13 Checking and filling of the oil circuit
- 7.14 Isolation test
- 7.15 Initial operation
- 8. Maintenance Instructions
- 8.1 Personal requirements
- 8.2 Personal requirements
- 8.3 Hazard notes for the maintenance and failure
- 8.4 Environmental protection
- 8.5 General maintenance instructions
- 8.6 Maintenance interval
- 8.7 Oil Change Intervals
- 8.8 Checking oil-level
- 8.9 Replacement of engine oil and engine oil filter
- 8.10 Verifying the starter battery and (if necessary) the battery bank
- 8.11 Checking the water separator in the fuel supply
- 8.12 De-aerating of the coolant circuit / freshwater
- 8.13 The raw water circuit
- 9. Generator Tables
- 10. Inverter Panda PMGi 5000
- Panda iControl2
- Current revision status
- Hardware
- 11. Safety instructions for the Panda iControl2
- 12. General operation
- 12.1 The Panda iControl2 panel
- 12.2 Starting preparation / Checks (daily)
- 12.3 Operation
- 12.4 Other operating functions
- 12.4.1 Set-up menu
- 12.4.2 Setting the brightness of the backlight ("backlight" and "dimtime")
- 12.4.3 The configuration menu ("config")
- 12.4.4 The network ID
- 12.4.5 Saving settings and exiting the set-up menu ("Save & Exit")
- 12.4.6 Activating/deactivating the autostart function ("Autostart")
- 12.4.7 Resetting the service interval ("Service")
- 12.4.8 Priming the fuel system ("Prime Fuel")
- 12.4.9 Selecting and saving a unit for the temperature value output
- 12.5 iControl2-Emergency-Stop
- 13. Installation
- 14. Maintenance
- 15. Annex
- 16. Warnings and error messages
- 16.1 Warnings
- 16.2 Faults
- 16.3 The error memory of the iControl 2 Panel
- 16.3.1 How to get to the error memory of the iControl2 Panel?
- 16.3.2 How are stored errors displayed?
- 16.3.3 How do I exit the error memory after having read the entries?
- 16.3.4 Can I delete the error memory?
- 16.3.5 Where are the errors stored?
- 16.3.6 In which language are the stored errors displayed?
- 16.3.7 Is it possible to upgrade an old iGenerator model by the error memory?

Installation Instructions
13.4.17 Kapitel/Chapter 7: Installation Instructions - Seite/Page 45
7. Installation Instructions
Attention!: Adapt system correctly.All connections (hoses, wires etc.) and installation
instructions are designed and suited for “standard”
installation situations.
In situations where Fischer Panda has no detailed
information concerning certain installation requirements
(such as vehicle specifications, maximum vehicle speed -
and all other conditions concerning special operating
situations) the installation instructions should be used as an
example guide only. The installation must be undertaken and
proved by a suitable qualified/trained person and should be
in accordance with the law as required by the country and
special situation.
Damages caused by faulty or incorrect installation are not
covered by the warranty.
7.1 Personal requirements
The described installation must be done by a technical trained person or a Fischer Panda service point.
7.1.1 Hazard notes for the installation
Notice:Follow the general safety instruction at the front of this
manual.
.Warning!: Automatic startDANGER TO LIFE! - Incorrect handling may lead to
health damage and to death.
Always disconnect the battery bank (first negative terminal
than positive terminal) before you work at the generator or
the electric system of the generator so that the generator
may not be started unintentionally.
Warning!: Risk of injuryImproper installation can result in severe personal
injuries or material damage. Therefore:
• Always undertake installation work when the generator is
switched off.
• Ensure there is sufficient installation clearance before start
working.
• Ensure tidiness and cleanliness at the workplace. Loose
components and tools lying around or on top of each other
are sources of accidents.
• Only perform installation work using commercially available
tools and special tools. Incorrect or damaged tools can
result injuries.