Seite/Page 68 - Kaptitel/Chapter 7: Installation Instructions 13.4.17
Fig. 7.12-1: Electrical installation - example
7.12.1 Installation PMGi inverter - See separate PMGi 5000 inverter manual
All electrical safety installations have to be made on board.
7.12.2 Power source selector
A power source selector switch must be installed between the PMGi power out and the ship's electrical supply
system. This switch must used to ensure that all AC consumers can be switched off at once. This switch should also
be installed to keep the generator and shore (grid) power systems separate.
1
2
3
4
1
1. Generator
2. Electrical fuel pump DC
3. PMGi 5000 inverter
4. iControl panel
5. Starter battery DC