Product Manual
Table Of Contents
- Marine Generator Manual
- Current revision status
- 3. General Instructions and Regulations
- 3.1 Safety first!
- 3.2 Tools
- 3.3 Manufacturer declaration in accordance with the Machinery Directive 2006/42/EC
- 3.4 Customer registration and guarantee
- 3.5 Safety Instructions - Safety First!
- 3.5.1 Safe operation
- 3.5.2 Observe safety instructions!
- 3.5.3 Personal protective clothing (PPE)
- 3.5.4 Cleanliness ensures safety
- 3.5.5 Safe handling of fuels and lubricants
- 3.5.6 Exhaust fumes and fire protection
- 3.5.7 Safety precautions against burns and battery explosions
- 3.5.8 Protect your hands and body from rotating parts!
- 3.5.9 Anti-freeze and disposal of fluids
- 3.5.10 Implementation of safety inspections and maintenance
- 3.6 Warning and instruction signs
- 4. In case of Emergency First Aid / Im Notfall - Erste Hilfe
- 5. Basics
- 5.1 Intended use of the machine
- 5.2 Purpose of the manual and description of the definitions of the trained persons/operators/users
- 5.3 Components of the i-system
- 5.4 Panda transport box
- 5.5 Opening the GFK sound insulation capsule
- 5.6 Transport and loading/unloading
- 5.7 Special service instructions and measures for extended machine downtimes and decommissioning
- 6. Panda 5000i PMS generator
- 7. Installation Instructions
- 7.1 Personal requirements
- 7.2 Place of installation
- 7.3 Generator Connections
- 7.4 Installation of the cooling system - raw water
- 7.4.1 General information
- 7.4.2 Installation of the through hull fitting in Yachts - scheme
- 7.4.3 Quality of the raw water sucking in line
- 7.4.4 Generator installation above waterline
- 7.4.5 Generator installation below waterline
- 7.4.6 First filling and ventilation of the internal cooling water circuit
- 7.4.7 Temperature check for controlling the cooling water circuit
- 7.5 Installation of the water cooled exhaust system
- 7.6 .Installation of the waterlock
- 7.7 Exhaust / water separator
- 7.8 Installation exhaust water separator
- 7.9 Fuel system installation
- 7.10 Ventilating the fuel system
- 7.11 Generator DC system installation
- 7.12 Generator AC System Installation
- 7.13 Checking and filling of the oil circuit
- 7.14 Isolation test
- 7.15 Initial operation
- 8. Maintenance Instructions
- 8.1 Personal requirements
- 8.2 Personal requirements
- 8.3 Hazard notes for the maintenance and failure
- 8.4 Environmental protection
- 8.5 General maintenance instructions
- 8.6 Maintenance interval
- 8.7 Oil Change Intervals
- 8.8 Checking oil-level
- 8.9 Replacement of engine oil and engine oil filter
- 8.10 Verifying the starter battery and (if necessary) the battery bank
- 8.11 Checking the water separator in the fuel supply
- 8.12 De-aerating of the coolant circuit / freshwater
- 8.13 The raw water circuit
- 9. Generator Tables
- 10. Inverter Panda PMGi 5000
- Panda iControl2
- Current revision status
- Hardware
- 11. Safety instructions for the Panda iControl2
- 12. General operation
- 12.1 The Panda iControl2 panel
- 12.2 Starting preparation / Checks (daily)
- 12.3 Operation
- 12.4 Other operating functions
- 12.4.1 Set-up menu
- 12.4.2 Setting the brightness of the backlight ("backlight" and "dimtime")
- 12.4.3 The configuration menu ("config")
- 12.4.4 The network ID
- 12.4.5 Saving settings and exiting the set-up menu ("Save & Exit")
- 12.4.6 Activating/deactivating the autostart function ("Autostart")
- 12.4.7 Resetting the service interval ("Service")
- 12.4.8 Priming the fuel system ("Prime Fuel")
- 12.4.9 Selecting and saving a unit for the temperature value output
- 12.5 iControl2-Emergency-Stop
- 13. Installation
- 14. Maintenance
- 15. Annex
- 16. Warnings and error messages
- 16.1 Warnings
- 16.2 Faults
- 16.3 The error memory of the iControl 2 Panel
- 16.3.1 How to get to the error memory of the iControl2 Panel?
- 16.3.2 How are stored errors displayed?
- 16.3.3 How do I exit the error memory after having read the entries?
- 16.3.4 Can I delete the error memory?
- 16.3.5 Where are the errors stored?
- 16.3.6 In which language are the stored errors displayed?
- 16.3.7 Is it possible to upgrade an old iGenerator model by the error memory?

Installation Instructions
13.4.17 Kapitel/Chapter 7: Installation Instructions - Seite/Page 69
Fig. 7.12.2-1: 3-Way Cam Switch3-Way Cam Switch
A 3-way cam switch should be used. This switch basic
positions: „Shore power“ - „OFF“ - „Generator“. If an (DC-AC)
inverter is used, a fourth position will be required.
0. OFF
I. Generator
II. Shore power connection
III. Inverter
The cam-type switch must have 2 poles, so that „MP“ and „phase“ can be switched off.
If a 3-phase current system is also installed with the option of supplying from either the generator or shore power, an
additional switch must be installed to keep these systems separate.
An alternative to a manual rotating switch is an automatic power relay. When the generator is not running, the relay
remains in the shore power position. As soon as the generator is running, the power relay switches automatically to
the generator position.
Note: If the system has both single and 3-phase AC, it is CRITICAL that the two systems remain SEPARATE!
Protection conductor
The generator is provided with a PEN safety system, as standard, which connects the 3-phase delta centre point „N“
to the safety ground strap.
If a separate ground protection cable is necessary (i.e. due to national safety regulations), the bridge between the
generator housing and ground (in the AC-Control box) must be disconnected. Once such a ground protection cable
is installed, it must be connected to the ground straps of all on board electrical devices.
In order to monitor the electrical system, it is recommended to install a voltmeter (and, if possible, a current meter)
down line from the power source selector switch so that all respective power sources can be monitored. A separate
voltmeter for the generator, itself, is therefore not required.
Electrical fuses
It is absolutely essential that the electrical system installation is inspected by a qualified electrical technician. The
generator should have its own AC input electrical fuses. The fuses should be sized such that the rated current of the
generator on each of the individual phases is not exceeded by more than 25%.
Data for gensets with power output greater than 30 kW on request!
The fuses must be of the slow type. A 3-way motor protection switch must be installed to protect the electrical motor.
Required fuses see Tabelle 9.1, “Diameter of conduits,” auf Seite 85
Required cable cross-sections
The following recommended electrical cable dimensions (cross sections) are the minimum required sizes for a safe
installation. (siehe Tabelle 9.1, “Diameter of conduits,” auf Seite 85)