Product Manual
Table Of Contents
- Marine Generator Manual
- Current revision status
- 3. General Instructions and Regulations
- 3.1 Safety first!
- 3.2 Tools
- 3.3 Manufacturer declaration in accordance with the Machinery Directive 2006/42/EC
- 3.4 Customer registration and guarantee
- 3.5 Safety Instructions - Safety First!
- 3.5.1 Safe operation
- 3.5.2 Observe safety instructions!
- 3.5.3 Personal protective clothing (PPE)
- 3.5.4 Cleanliness ensures safety
- 3.5.5 Safe handling of fuels and lubricants
- 3.5.6 Exhaust fumes and fire protection
- 3.5.7 Safety precautions against burns and battery explosions
- 3.5.8 Protect your hands and body from rotating parts!
- 3.5.9 Anti-freeze and disposal of fluids
- 3.5.10 Implementation of safety inspections and maintenance
- 3.6 Warning and instruction signs
- 4. In case of Emergency First Aid / Im Notfall - Erste Hilfe
- 5. Basics
- 5.1 Intended use of the machine
- 5.2 Purpose of the manual and description of the definitions of the trained persons/operators/users
- 5.3 Components of the i-system
- 5.4 Panda transport box
- 5.5 Opening the GFK sound insulation capsule
- 5.6 Transport and loading/unloading
- 5.7 Special service instructions and measures for extended machine downtimes and decommissioning
- 6. Panda 5000i PMS generator
- 7. Installation Instructions
- 7.1 Personal requirements
- 7.2 Place of installation
- 7.3 Generator Connections
- 7.4 Installation of the cooling system - raw water
- 7.4.1 General information
- 7.4.2 Installation of the through hull fitting in Yachts - scheme
- 7.4.3 Quality of the raw water sucking in line
- 7.4.4 Generator installation above waterline
- 7.4.5 Generator installation below waterline
- 7.4.6 First filling and ventilation of the internal cooling water circuit
- 7.4.7 Temperature check for controlling the cooling water circuit
- 7.5 Installation of the water cooled exhaust system
- 7.6 .Installation of the waterlock
- 7.7 Exhaust / water separator
- 7.8 Installation exhaust water separator
- 7.9 Fuel system installation
- 7.10 Ventilating the fuel system
- 7.11 Generator DC system installation
- 7.12 Generator AC System Installation
- 7.13 Checking and filling of the oil circuit
- 7.14 Isolation test
- 7.15 Initial operation
- 8. Maintenance Instructions
- 8.1 Personal requirements
- 8.2 Personal requirements
- 8.3 Hazard notes for the maintenance and failure
- 8.4 Environmental protection
- 8.5 General maintenance instructions
- 8.6 Maintenance interval
- 8.7 Oil Change Intervals
- 8.8 Checking oil-level
- 8.9 Replacement of engine oil and engine oil filter
- 8.10 Verifying the starter battery and (if necessary) the battery bank
- 8.11 Checking the water separator in the fuel supply
- 8.12 De-aerating of the coolant circuit / freshwater
- 8.13 The raw water circuit
- 9. Generator Tables
- 10. Inverter Panda PMGi 5000
- Panda iControl2
- Current revision status
- Hardware
- 11. Safety instructions for the Panda iControl2
- 12. General operation
- 12.1 The Panda iControl2 panel
- 12.2 Starting preparation / Checks (daily)
- 12.3 Operation
- 12.4 Other operating functions
- 12.4.1 Set-up menu
- 12.4.2 Setting the brightness of the backlight ("backlight" and "dimtime")
- 12.4.3 The configuration menu ("config")
- 12.4.4 The network ID
- 12.4.5 Saving settings and exiting the set-up menu ("Save & Exit")
- 12.4.6 Activating/deactivating the autostart function ("Autostart")
- 12.4.7 Resetting the service interval ("Service")
- 12.4.8 Priming the fuel system ("Prime Fuel")
- 12.4.9 Selecting and saving a unit for the temperature value output
- 12.5 iControl2-Emergency-Stop
- 13. Installation
- 14. Maintenance
- 15. Annex
- 16. Warnings and error messages
- 16.1 Warnings
- 16.2 Faults
- 16.3 The error memory of the iControl 2 Panel
- 16.3.1 How to get to the error memory of the iControl2 Panel?
- 16.3.2 How are stored errors displayed?
- 16.3.3 How do I exit the error memory after having read the entries?
- 16.3.4 Can I delete the error memory?
- 16.3.5 Where are the errors stored?
- 16.3.6 In which language are the stored errors displayed?
- 16.3.7 Is it possible to upgrade an old iGenerator model by the error memory?

Inverter Panda PMGi 5000
13.4.17 Kapitel/Chapter 10: Inverter Panda PMGi 5000 - Seite/Page 97
10.6 Operation manual
10.6.1 Primary remarks / Winter operation
The PMGi can operate in the range of -20 °C to +40 °C.
10.6.2 Load at the PMGi
Do not overload the PMGi. It will go on error.
10.6.3 Automatic start
The generator can start (depending on the remote control panel) by an external signal (automatic start)
If you use this option make sure that the load is connected to the PMGi after the output has reached the nominal
230 V / 50 Hz and not to overload the PMGi (some electronic devices, such like air conditions, need an higher start
current). May use a relay which connect the load at 230 V.
10.7 Status LED´s
Red - Green
10.8 Cooling of the PMGi
Inside of the PMGi a fan is mounted.
Do not cover the air holes and grille.
The heat sink and the fan of the PMGi may become dirty as a consequence of the use of the generator, and so the
unit can loose a part of their heat transfer characteristic. Every 6 months it is necessary to visual inspect the heat
sinks and clean it with compressed air. At every Generator service the fan of the PMGi should be cleaned by the
special trained person.
LED - Red Red LED lights for the very first seconds (about 10 sec) after the running of the engine. During this time no output is
provided by the PMGi.
Red LED starts to blink when an overload condition is reached. During this time the green LED continiues to light.
When an overload condition stays for too long the red LED stops blinking and stays permanently switched on, while the
green LED switch off.
LED-Green Green LED permanently lights alone when the PMGi output is available and it value stays in the spacification