Product Manual
Table Of Contents
- Marine Generator Manual
- Current revision status
- 3. General Instructions and Regulations
- 3.1 Safety first!
- 3.2 Tools
- 3.3 Manufacturer declaration in accordance with the Machinery Directive 2006/42/EC
- 3.4 Customer registration and guarantee
- 3.5 Safety Instructions - Safety First!
- 3.5.1 Safe operation
- 3.5.2 Observe safety instructions!
- 3.5.3 Personal protective clothing (PPE)
- 3.5.4 Cleanliness ensures safety
- 3.5.5 Safe handling of fuels and lubricants
- 3.5.6 Exhaust fumes and fire protection
- 3.5.7 Safety precautions against burns and battery explosions
- 3.5.8 Protect your hands and body from rotating parts!
- 3.5.9 Anti-freeze and disposal of fluids
- 3.5.10 Implementation of safety inspections and maintenance
- 3.6 Warning and instruction signs
- 4. In case of Emergency First Aid / Im Notfall - Erste Hilfe
- 5. Basics
- 5.1 Intended use of the machine
- 5.2 Purpose of the manual and description of the definitions of the trained persons/operators/users
- 5.3 Components of the i-system
- 5.4 Panda transport box
- 5.5 Opening the GFK sound insulation capsule
- 5.6 Transport and loading/unloading
- 5.7 Special service instructions and measures for extended machine downtimes and decommissioning
- 6. Panda 5000i PMS generator
- 7. Installation Instructions
- 7.1 Personal requirements
- 7.2 Place of installation
- 7.3 Generator Connections
- 7.4 Installation of the cooling system - raw water
- 7.4.1 General information
- 7.4.2 Installation of the through hull fitting in Yachts - scheme
- 7.4.3 Quality of the raw water sucking in line
- 7.4.4 Generator installation above waterline
- 7.4.5 Generator installation below waterline
- 7.4.6 First filling and ventilation of the internal cooling water circuit
- 7.4.7 Temperature check for controlling the cooling water circuit
- 7.5 Installation of the water cooled exhaust system
- 7.6 .Installation of the waterlock
- 7.7 Exhaust / water separator
- 7.8 Installation exhaust water separator
- 7.9 Fuel system installation
- 7.10 Ventilating the fuel system
- 7.11 Generator DC system installation
- 7.12 Generator AC System Installation
- 7.13 Checking and filling of the oil circuit
- 7.14 Isolation test
- 7.15 Initial operation
- 8. Maintenance Instructions
- 8.1 Personal requirements
- 8.2 Personal requirements
- 8.3 Hazard notes for the maintenance and failure
- 8.4 Environmental protection
- 8.5 General maintenance instructions
- 8.6 Maintenance interval
- 8.7 Oil Change Intervals
- 8.8 Checking oil-level
- 8.9 Replacement of engine oil and engine oil filter
- 8.10 Verifying the starter battery and (if necessary) the battery bank
- 8.11 Checking the water separator in the fuel supply
- 8.12 De-aerating of the coolant circuit / freshwater
- 8.13 The raw water circuit
- 9. Generator Tables
- 10. Inverter Panda PMGi 5000
- Panda iControl2
- Current revision status
- Hardware
- 11. Safety instructions for the Panda iControl2
- 12. General operation
- 12.1 The Panda iControl2 panel
- 12.2 Starting preparation / Checks (daily)
- 12.3 Operation
- 12.4 Other operating functions
- 12.4.1 Set-up menu
- 12.4.2 Setting the brightness of the backlight ("backlight" and "dimtime")
- 12.4.3 The configuration menu ("config")
- 12.4.4 The network ID
- 12.4.5 Saving settings and exiting the set-up menu ("Save & Exit")
- 12.4.6 Activating/deactivating the autostart function ("Autostart")
- 12.4.7 Resetting the service interval ("Service")
- 12.4.8 Priming the fuel system ("Prime Fuel")
- 12.4.9 Selecting and saving a unit for the temperature value output
- 12.5 iControl2-Emergency-Stop
- 13. Installation
- 14. Maintenance
- 15. Annex
- 16. Warnings and error messages
- 16.1 Warnings
- 16.2 Faults
- 16.3 The error memory of the iControl 2 Panel
- 16.3.1 How to get to the error memory of the iControl2 Panel?
- 16.3.2 How are stored errors displayed?
- 16.3.3 How do I exit the error memory after having read the entries?
- 16.3.4 Can I delete the error memory?
- 16.3.5 Where are the errors stored?
- 16.3.6 In which language are the stored errors displayed?
- 16.3.7 Is it possible to upgrade an old iGenerator model by the error memory?

Inverter Panda PMGi 5000
Seite/Page 98 - Kaptitel/Chapter 10: Inverter Panda PMGi 5000 13.4.17
10.9 Installation of the PMGi
The PMGi must be mounted vertical, with the electrical connection down. So you can read the writing on the PMGi.
The surface where the PMGi is mounted should be smoothed and support the heat transfer. The Air holes and Air
grille must be not covered and enough cooling air must be pleasant at any time for the PMGi.
To mount the PMGi use the fixing holes diameter 6,5mm.
Note!See the safety instruction in your Generator and iControl
Manual.
The rules of the respective regional authority must be adhered to. Only an electrician may carry out installation of the
electrical connections for safety reasons.
10.9.1 Electrical connection.
Only special trained persons are allowed to make the electrical connection.
When an extension cable is required, be sure to use a though rubber sheeted flexible and fireproof cable. Limit
length of extension cables depends on the voltage drop along the cable. This drop must be less than 2,5 % value of
the nominal output voltage.
Pay attention to the right pin assignment. See “Socket pins of the PMGi 5000” on page 93.
10.9.1.1 Connection to a system with RCD
The PMGi is prepared for the use in a RCD protected grid.,
The PMGi out must be connected 1:1 (PE,N,L) to the customers electrical cabinet. The Life wire and neutral wire will
be connected to the RCD. The PE will be connected to the PE of the electrical cabinet. After installation the function
of the RCD must be tested.