13.4.17 Kapitel/Chapter 10: Inverter Panda PMGi 5000 - Seite/Page 99
Fig. 10.9-1: PE-N bridgePE-N Bridge
Inside of the PMGi a PE-N bridge
10.9.1.2 Connection to a system with isolation control
For the use of the PMGi with an isolation controlled grid, the internal PWE-N Bridge must be disconnected.
A Manual for this modification can be downloaded under:
http://www.fischerpanda.de/images/gensets/M_AC_50_INV_PMS_8000i/operatormanual/PMGi/
Modification_PMGi_isolation_control.eng.pdf
10.10Technical data
10.10.1 General data
PMGi is part of the Panda i-series generator. It´s not allowed to be used with other generators or aplications.
10.10.2 Generator spezification
1
Storage temperature PMGi -2C to +5C
Working temperature PMGi Minimum: -20 °C
Maximum: +40 °C
Maximale internel temperature of the PMGi:
+60 °C
PMG Generator out 3 phase
Voltage Phase minimum 140 V AC Maximum 250 V AC
Frequency minimum 250 Hz Maximum 400 Hz