Planning File

0 100 200 400
millimetres
DATA SHEET
30" Classic Freestanding Range Gas
INDICATES CLEARANCES ---------------
INDICATES PRODUCT DATUM --------------------
DATE: 12.03.2019
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Please read the installation manual for detailed information on installing the
product. For full installation instructions & specifications visit fisherpaykel.com
Model no:
OR30SCG4X1, OR30SCG4B1, OR30SCG4W1, OR30SCG4R1
(refer page 5 for metric measurements)
Clearance Dimensions
mm
a Minimum width of ventilation hood installed above range
- not shown*
762
B Minimum vertical distance between countertop and cabinet
extending above counter
457
c Minimum clearance from left and right of range to nearest
vertical combustible surface
330
d Minimum clearance from cooking surface to:
- overhead cabinet centred above the cooktop
(combustible / unprotected)
- overhead cabinet centred above the cooktop
(non-combustible / protected)
- ventilation hood centred above the cooktop
914
762
762
e Maximum overall depth of overhead cabinetry
330
f Distance from center of rear burner to rear of product
225
*IMPORTANT NOTE: For full installation and clearance details please refer to
our installation manual.
FRONT VIEW
PLAN VIEW
PROFILE VIEW
DATUM : BOTTOM OF CHASSIS
DATUM :
TOP OF COUNTERTOP
FRONT OF SIDE PANEL
FRONT OF SIDE PANEL
MINIMUM CLEARANCE:
COMBUSTIBLE SURFACE
MAXIMUM OVERALL DEPTH
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
ADJACENT OVERHEAD CABINET
MINIMUM CLEARANCE:
NON-COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
LEFT AND RIGHT OF RANGE
TO NEAREST VERTICAL
COMBUSTIBLE SURFACE
D
E
D
B
C
F
C