Cooktop User Manual

7
5
CLEARANCE DIMENSIONS
Clearance dimensions (mm)
CG302D
CG451D
CG603D
CG604D
CG752D
CG903D
CG905D
A
minimum clearance from left edge of cutout to nearest combustible surface 120 60 115 130 115 115 130
B
minimum clearance from right edge of cutout to nearest combustible surface 120 60 115 115 115 115 115
C
minimum clearance from rear edge of cutout to:
nearest combustible surface
nearest non-combustible surface
160
45
85
45
160
45
160
45
125
45
125
45
160
45
D
minimum height of non-combustible material when used on adjacent walls 150 150 150 150 150 150 150
E
minimum clearance from glass surface to:
rangehood
any other overhead exhaust fan
downward facing combustible surface
downwards-facing tiled or  re resistant surface
650
800
650
500
650
800
650
500
650
800
650
500
650
800
650
500
650
800
650
500
650
800
650
500
650
800
650
500
F
minimum clearance below top of benchtop to:
combustible surface
Fisher & Paykel oven or nearest non-combustible surface
70
65
70
65
70
65
70
65
70
65
70
65
70
65
G
minimum distance from right edge of cooktop to gas connection point on wall
(if using a  exible hose)
250 250 250 250 250 250 250
H
distance from  oor to gas connection point on wall (if using a  exible hose)
min. 800 -
max. 850
min. 800 -
max. 850
min. 800 -
max. 850
min. 800 -
max. 850
min. 800 -
max. 850
min. 800 -
max. 850
min. 800 -
max. 850
I
maximum overall depth of overhead cabinetry 600 600 600 600 600 600 600
Note: Ensure there is an earthed power outlet within 900 mm of the centre rear of the product. The gas connector on the wall should be 800-850 mm (H) above the  oor and to a distance of at least 250 mm (G) outside the width
of the product, on the right-hand side. It should be accessible with the product installed.
FRONT
ISO
E
H
D
F
G
A
I
B
C