Installation Guide

CLEARANCES — 300MM MODELS
A
H
f f
b
D
E
C
C
g
i
j
*Combustible surface definition
Any materials of a building structure or decorative structure made of wood, compressed paper,
plant fibres, vinyl/plastic or other materials that are capable of transferring heat or being
ignited and burned. Such material shall be considered combustible even though flame-proofed,
fire-retardant treated or surface-painted, or plastered.
Ensure there is an earthed power outlet within 900mm of the centre rear of the product. The gas
connector on the wall should be accessible with the product installed.
CLEARANCE DIMENSIONS
CG301D CG302D
MM MM
A Minimum clearance from top of trivets to:
z
Rangehood 650 650
z
Overhead exhaust fan 800 800
z
Downward facing combustible surface* 650 650
z
Downwards-facing tiled or fire resistant surface 500 500
B Minimum clearance below bench top to:
z
Combustible surface 70 70
z
Fisher & Paykel oven or nearest non-combustible surface 65 65
C Minimum clearance from cutout to nearest combustible surface 120 120
D Minimum distance from right edge of cooktop to gas
connection point on wall (if using a flexible hose)
250 250
E Distance from floor to gas connection point on wall
(if using a flexible hose)
800-850 800-850
F Minimum clearance from countertop to overhead cabinet
(not directly above the cooktop)
450 450
G Maximum depth of overhead cabinetry 600 600
H Minimum distance between overhead cabinets
(either side of the cooktop)
315 315
I Minimum clearance from rear edge of cutout to nearest:
z
Combustible surface 160 160
z
Non-combustible surface 45 45
J Minimum clearance from front edge of cutout to counter front 35 35
15