COMBI: GAS + INDUCTION COOKTOP MINIMAL CGI905DNGTB4, CGI905DLPTB4, CGI603DNGTB4, CGI603DLPTB4 INSTALLATION GUIDE NZ AU
! WARNING! If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. NEVER use this appliance as a space heater to heat or warm the room. Doing so may result in carbon monoxide poisoning and overheating of the appliance. What to Do if you Smell Gas • Do not try to light any appliance.
SAFETY AND WARNINGS ! WARNING! Electric Shock Hazard Failure to follow this advice may result in electric shock or death. • Disconnect the appliance from the mains electricity supply before carrying out any work or maintenance. • Connection to a good earth wiring system is essential and mandatory. • Alterations to the domestic wiring system must only be made by a qualified electrician. ! WARNING! Cut Hazard Failure to use caution could result in injury. • Take care: some edges are sharp.
INITIAL CONSIDERATIONS PRIOR TO INSTALLATION Prior to installing your cooktop, ensure the following: z z z z z z z z z z 4 The local distribution conditions (nature of gas and pressure) and the adjustment of the appliance are compatible. For adjustment conditions for this appliance see ‘Gas rate summary’. A suitable disconnection switch is incorporated in the permanent wiring, mounted and positioned to comply with the local wiring rules and regulations.
COMPONENTS REQUIRED PARTS SUPPLIED z z z TOOLS REQUIRED Keep all packing materials until the unit has been inspected. Inspect the product to ensure there is no shipping damage. If any damage is detected contact the dealer or retailer you bought the product from to report the damage. Fisher & Paykel is not responsible for shipping damage.
PRODUCT DIMENSIONS — CGI603D MODELS B PRODUCT DIMENSIONS m C PLAN ISOMETRIC l G a D e FRONT k H F PROFILE i 126 B Overall width of cooktop 599 C Overall depth of cooktop 530 D Height of chassis 60 E Width of chassis 556 F Depth of chassis 485 G Height of cooktop glass and flange 5 H Depth of front overhang of cooktop 12 I Depth of rear overhang of cooktop glass** 33 J Depth of left overhang of cooktop glass** 23 K Depth of right overhang of cooktop glass** 20 L Height o
PRODUCT DIMENSIONS — CGI905D MODELS B PRODUCT DIMENSIONS m A Overall height of cooktop* C PLAN ISOMETRIC l G a D j e FRONT k H F PROFILE i CGI905D MM 126 B Overall width of cooktop 899 C Overall depth of cooktop 530 D Height of chassis 60 E Width of chassis 852 F Depth of chassis 485 G Height of cooktop glass and flange 5 H Depth of front overhang of cooktop 12 I Depth of rear overhang of cooktop glass** 33 J Depth of left overhang of cooktop glass** 23 K Depth of right o
CUTOUT DIMENSIONS — CGI603D MODELS PROUD INSTALLATION FLUSH INSTALLATION A A E C B f B G H C PLAN PLAN D FRONT CUTOUT DIMENSIONS FRONT CGI603D MM CUTOUT DIMENSIONS MM A Overall width of cutout 560 A Overall width of routered recess 605 B Overall depth of cutout 490 B Overall depth of routered recess 535 C Corner radius of cutout max 2 C Offset overhang allowance D Height of routered recess 34 5 E Width of cutout 560 F Depth of cutout 490 G Corner radius of routered recess H
CUTOUT DIMENSIONS — CGI905D MODELS PROUD INSTALLATION FLUSH INSTALLATION A A E C B f B G H C PLAN PLAN D FRONT CUTOUT DIMENSIONS FRONT CGI905D MM CUTOUT DIMENSIONS CGI905D MM A Overall width of cutout 865 A Overall width of routered recess 905 B Overall depth of cutout 490 B Overall depth of routered recess 535 C Corner radius of cutout max 2 C Offset overhang allowance D Height of routered recess 34 5 E Width of cutout 865 F Depth of cutout 490 G Corner radius of routered
CLEARANCES — CGI603D MODELS H CLEARANCE DIMENSIONS CGI603D MM A Minimum clearance from top of trivets to: A f f b z Rangehood 650 z Overhead exhaust fan 800 z Downward facing combustible surface* 650 z Downwards-facing tiled or fire resistant surface 500 B Minimum clearance below bench top to: D E z Combustible surface 70 z Fisher & Paykel oven or nearest non-combustible surface 65 C Minimum clearance from side of cutout to nearest adjacent combustible surface 115 D Minimum dist
CLEARANCES — CGI905D MODELS H CLEARANCE DIMENSIONS CGI905D MM A Minimum clearance from top of trivets to: A f f b z Rangehood 650 z Overhead exhaust fan 800 z Downward facing combustible surface* 650 z Downwards-facing tiled or fire resistant surface 500 B Minimum clearance below bench top to: D E z Combustible surface 70 z Fisher & Paykel oven or nearest non-combustible surface 65 C Minimum clearance from side of cutout to nearest adjacent combustible surface 115 D Minimum dist
VENTING CLEARANCES DRAWER OR OTHER OBSTRUCTION OVEN WITH COOLING FAN This cooktop requires adequate supply of cool air to fully function. The base of the cooktop must have direct unrestricted ventilation to the room where the cooktop is installed. There must be a 4mm air gap at the front of the cooktop.
GAS CONNECTION CONSIDERATIONS The following are the available options for connecting the gas line to the cooktop to suit your installation: GAS LINE TO GAS INLET GAS LINE TO ELBOW FACING LEFT GAS LINE TO ELBOW FACING DOWN ISO ISO ISO BASE BASE BASE NATURAL GAS MODELS 65mm 34mm 85mm Ensure the supplied natural gas test point adapter dimensions are considered prior to the installation. This can be fitted at any point along the gas line.
GAS RATE SUMMARY CGI603D MODELS CGI905D MODELS 1 1 BURNER GAS TYPE JET SIZE (MM) NOMINAL RATING (MJ/H) BURNER GAS TYPE 1.45 NG (1.00kPa)* 1.45 21.50 0.81 NG (1.00kPa)* 20.50 14 21.50 0.81 ULPG (2.75kPa)* 0.50 *Nominal pressure with burner on high 1.45 0.70 1 Dual wok 0.81 ULPG (2.75kPa)* NOMINAL RATING (MJ/H) 1.45 0.70 1 Dual wok JET SIZE (MM) 0.81 0.50 *Nominal pressure with burner on high 20.
PROUD INSTALLATION Fit the elbow and washer to the floating nut. Turn the cooktop over carefully and place onto a protected surface ensuring the ignitor won’t be damaged. 1 elbow* washer 4 Locate the side brackets* to the appropriate slots on the cooktop chassis. The correct slot height is determined by the thickness of your countertop. floating nut Apply adhesive foam seal around the glass overhang, 5mm in from the edge of the glass.
FLUSH INSTALLATION 1 Prepare the countertop for flush installation. Use a router to cutout the edges of the countertop to specified depth (5mm). adhesive 4 Attach an adhesive tape along the edges of the routered recess. 5 elbow* washer floating nut 6 Gently lower the cooktop into the cutout ensuring you have access below the countertop to fit and secure the brackets. 7 *The number of brackets varies based on your cooktop model 16 Tighten all screws to secure the cooktop to the countertop.
GAS CONNECTION NG Models NATURAL GAS MODELS LEAK TESTING GAS Adjust to obtain a test point pressure of 1kPa with the burner operating at the highest setting. ON Manual shut-off valve LPG Models LPG MODELS z z z Adjust to obtain a test point pressure of 2.75kPa with the burner operating at the highest setting. Leak test points Ensure all dials are set to OFF before connecting cooktop to gas supply.
ELECTRICAL CONNECTION CGI905D SINGLE PHASE CONNECTION Before connecting the cooktop to the mains power supply check that: z z z The domestic wiring system is suitable for the power drawn by the cooktop. The voltage corresponds to the value given in the rating plate. The power supply cable sections can withstand the load specified on the rating plate. MODEL MAX. CURRENT DRAW MAX.
COOKTOP BURNERS ATTACH PAN SUPPORTS TEST BURNERS lifting off yellow tip stable blue flame Securely locate all pan supports ensuring they are the installed in the correct orientation and do not rock. z z z z z z z z To check that the ignition system operates correctly, light the burner. Check for a well-defined blue flame without any yellow tipping. If any abnormality is evident, check that the components of the burner assembly are located properly.
INSTALLER CHECKLIST TO BE COMPLETED BY THE INSTALLER GENERAL Read safety and warnings in the user guide before operating the cooktop. GAS Specified clearance maintained. Manual gas shut-off valve installed in an accessible location. Unit is level – front to back and side to side. Unit tested and free of gas leaks. All packaging materials have been removed. ELECTRICAL Dials turn correctly and freely. Receptacle with correctly rated over-current protection is provided for service cord connection.
FISHERPAYKEL.COM © Fisher & Paykel Appliances 2020. All rights reserved. The models shown in this guide may not be available in all markets and are subject to change at any time. The product specifications in this guide apply to the specific products and models described at the date of issue. Under our policy of continuous product improvement, these specifications may change at any time.