Installation Guide

ELECTRICAL CONNECTION
PE
1
2
3
4
5
PE
1
2
3
4
5
N
L
N
L
1 L2
PE
1
2
3
4
5
N
L
1 L3L2
PE
1
2
3
4
5
N
L
Single-phase connection (220-240 V~) Ensure cable is tightened with screw.
You may have to remove the screw first
before fitting the clamp.
SINGLE-PHASE CONNECTION (220-240 V~)
This cooktop must be connected to the mains power supply only by a suitably qualified
person. To connect the cooktop to the mains power supply, do not use adapters, reducers, or
branching devices, as they can cause overheating and fire. The power supply cable must not
touch any hot parts and must be positioned so that its temperature will not exceed 75°C at
any point. Check with an electrician whether the domestic wiring system is suitable without
alterations. Any alterations must only be made by a qualified electrician.
Before connecting the cooktop to the mains power supply check that:
z
The domestic wiring system is suitable for the power drawn by the cooktop.
z
The voltage corresponds to the value given in the rating plate.
z
The power supply cable sections can withstand the load specified on the rating plate.
MODEL MAX. CURRENT DRAW MAX. LOAD VOLTAGE
CI302CTB* 16A 3700W 220 – 240V 1N ~
CI604CTB 32A 7400W 220 – 240V 1N ~
CI704CTB 32A 7400W 220 – 240V 1N ~
CI804CTB 32A 7400W 220 – 240V 1N ~
CI904CTB 32A 7400W 220 – 240V 1N ~
*The CI302CTB is supplied with a cable. This must be wired into a suitably rated plug, permanent
connection outlet or power isolator.
L N
E
clamp
screw
23