Installation Guide

5
B
D
E
C
C
A
FRONT
ISO
CI302DTB CI603DTB CI604DTB CI754DTB CI905DTB
CLEARANCE DIMENSIONS mm mm mm mm mm
A
Minimum clearance from rear edge of cutout to nearest combustible surface 30 30 30 30 30
B
Minimum clearance from glass surface to rangehood
650 650 650 650 650
C
Minimum clearance from side edges of cutout to nearest combustible surface
30 30 30 25 25
D
Minimum clearance from benchtop to overhead cabinet not directly above the
cooktop
450 450 450 450 450
E
Minimum clearance below top of benchtop to:
Rear top of oven* installed below cooktop or cabinetry
65 65 65 65 65
* The oven installed below the cooktop MUST have a cooling fan.
4 CLEARANCE DIMENSIONS
min. 75 mm
Alternatively
2x 50mm holes
in side wall to allow
adequate cool air
min. 4 mm
min. 4 mm
Drawer or other obstruction
Oven with cooling fan
Ventilation gap
must be present
20 mm
E
Alternatively
2x 50mm holes
in side wall to allow
adequate cool air
Ventilation gap
must be present
20 mm
Some ovens require
installation in a sealed
box. Please refer to oven
install guide for full specs.
Dimension E = from top of
cabinetry/box.
WARNING!
!
This cooktop requires adequate supply of cool air
to fully function. The base of the cooktop must have
direct unrestricted ventilation to the room where the
cooktop is installed. There must be a 4mm air gap
at the front of the cooktop (as shown on diagram
above). Follow the requirements shown.