Installation Guide

5
C. Vertical Exhaust: Outside Ventilation
1. Remove and save the 4 screws from the Fan Cover Bracket. Re-
move Fan Cover Bracket by sliding it in the opposite direction of
the arrow on the Fan Cover Bracket as shown in Figure 13.
2. Lift the Hood Fan Unit carefully and slip wires out of cavity. See
Figure 14.
CAUTION: Do not pull or stretch hood fan wiring.
3 Rotate the Hood Fan Unit 180˚ so that the fan blade openings are
facing the back of the oven. Note, you will need to lift the wire
over the hood fan unit so the wire will clear. See Figure 15 (A). Then rotate the Hood Fan Unit 90˚ so that the
fan blade openings are facing the top of the oven. See Figure 15 (B). Replace Hood Fan Unit into the oven.
Be careful not to pinch the lead wire between the inner bracket and the Hood Fan Unit. Put the lead wire into
Wire Box. See Figure 15 (C).
4. Replace the Fan Cover Bracket. Make sure the fan blades are visible through the top openings in the oven
before proceeding.
5. Attach the Fan Cover Bracket to unit with the 4 screws removed in step 1 above. See Figure 16. The Hood Fan
Unit is now rotated for vertical exhaust operation.
6. Attach the Exhaust Damper Assembly to the fan cover on the top of the outercase cabinet by sliding it into
the slits in the same direction as the arrow. Use 1 Tapping Screw 4 x12 mm from the INSTALLATION HARD-
WARE and tighten into place. See Figure 17.
Mounting Plate (back side)
Figure 12
Figure 13
Figure 15
Figure 14
Figure 16
Figure 17
Fan Cover Bracket
(A) Rotate 180˚
(C)
(B)
Wire Box
Exhaust Damper Assembly