Installation Guide

11
30"
26-1/2"
12" Min. to Combustibles
without Backguard
15/16"
12"
Wall Mount
Low Backguard
Base Cabinet
Wall Mount
Full Backguard
36Min. to
Combustibles
36Min. to
Combustibles
8-5/16"
24"
28"
1-19/32" To Center
Line of Gas Inlet
5/16"
Cabinet face for installation
with projecting control panel
Cabinet face for installation
with ush control panel
2-1/2"
Countertop level
As dened in the “National Fuel Gas Code(ANSI Z223.1, latest edition).
Base Cabinet
9 ELECTRICAL CONNECTION
IMPORTANT!
This cooktop must be grounded.
Always disconnect electric supply cord from the
wall outlet or service disconnect before servicing
this appliance.
Observe all governing codes and ordinances
when grounding, in absence of which, observe
National Electrical Code ANSI / NFPA No. 70.
The rating label is located
on the right-hand side of the
cooktop, towards the front.
A wiring diagram
label is attached
to the bottom of
the cooktop
The electrical supply must be a correctly polarized, grounded 120 V AC, 60 Hz, single phase circuit suitable for the maximum current draw of the
model, as detailed in the table below. Please verify your model’s current draw by checking the rating label on the cooktop.
Required grounding method
This appliance is factory equipped with a power supply cord with a three-prong grounding plug (with polarized parallel blades). It must be plugged
into a mating grounding type receptacle, connected to a correctly polarized 120 Volt circuit. If the circuit does not have a grounding type receptacle,
it is the responsibility and obligation of the installer to have the existing receptacle changed to a properly grounded and polarized receptacle in
accordance with all applicable local codes and ordinances by a qualified electrician. In the absence of local codes and ordinances, the receptacle
replacement shall be in accordance with the National Electrical Code.
IMPORTANT!
The third prong should not, under ANY circumstances, be cut or removed.
Receptacle Box
Cover Plate
Three Prong
Receptacle
Three
Prong
Plug
MODEL MAX. CURRENT DRAW CIRCUIT
CPV2-30” models 15 A 15 A
CPV2-36” models 15 A 15 A
CPV2-48” models 15 A 15 A
Island Installation