Quick Start Guide

9
7COOKTOP INSTALLATION SCENARIOS AND USE OF BACKGUARDS
Important notes
There are three different backguards available for purchase:
Wall Mount Low Backguard
Wall Mount High Backguard with Low Shelf
Wall Mount High Backguard with High Shelf.
For installations against non-combustible* surfaces only, you may install the cooktop without a backguard or choose any of the three backguards.
For installations close to combustible surfaces (above the cooking surface), without a backguard, there must be a minimum 6” (152mm) clearance (see Scenario 2 or 7 opposite)
For installations immediately against combustible surfaces (above the cooking surface), you must purchase the Wall Mount High Backguard High Shelf (scenario 5 opposite).
The cooking surface must sit flush or above the adjacent countertop level.
Note: Backguard Installation Instructions can also be downloaded from our website www.fisherpaykel.com
* Non-combustible surfaces:
as defined in ‘National Fuel Gas Code’ (ANSI Z223.1, Current Edition). Clearances from non-combustible materials
are not part of the ANSI Z21.1 scope and are not certified by UL. Clearances of less than 6” (152mm) must be
approved by the local codes and/or by the local authority having jurisdiction.
BACKGUARD MODEL NUMBERS
COOKTOP
WALL
MOUNT LOW
BACKGUARD
WALL
MOUNT HIGH
BACKGUARD
LOW SHELF
WALL
MOUNT HIGH
BACKGUARD
HIGH SHELF
BACKGUARD
WIDTH
30” models BGCV2-1230 BGCV2-3030 BGCV2-3030H 29 7/8” (759mm)
36” models BGCV2-1236 BGCV2-3036 BGCV2-3036H 35 7/8” (911mm)
48” models BGCV2-1248 BGCV2-3048 BGCV2-3048H 47 7/8” (1216mm)