5PRODUCT & CUTOUT DIMENSIONS – ALL MODELS
Note: Gas inlet connection is located in the
rear left corner.
CPV2-486GD model shown
for illustration purposes only
TOP
TOP
FRONT
SIDE
PRODUCT AND CUTOUT DIMENSIONS
30” MODELS 36” MODELS 48” MODELS
inches (mm) inches (mm) inches (mm)
A
Height below countertop to bottom of chassis / Height of cutout 8” (203) 8” (203) 8” (203)
B
Overall height of product (bottom of chassis to top of grates) 9 15/16’’ (253) 9 15/16’’ (253) 9 15/16’’ (253)
C
Overall width of cooktop 29 7/8’’ (759) 35 7/8’’ (911) 47 7/8’’ (1216)
D
Overall depth of cooktop 28 1/8’’ (714) 28 1/8’’ (714) 28 1/8’’ (714)
E
Height above countertop to top of grates 1 15/16’’ (50) 1 15/16’’ (50) 1 15/16’’ (50)
F
Height from countertop to chassis top surface 3/8” (10) 3/8” (10) 3/8” (10)
G
Height of chassis 8 3/8’’ (213) 8 3/8’’ (213) 8 3/8’’ (213)
H
Distance from left edge of chassis to center line of gas inlet 2 1/2’’ (63) 2 1/2’’ (63) 3’’ (77)
I
Distance from left edge of chassis to center line of power cord 10 5/8’’ (270) 10 5/8’’ (270) 10 5/8’’ (270)
J
Width of cutout min 30” (762) min 36” (915) min 48” (1219)
K
Depth of cutout for projecting control panel 24 3/16’’ (614) 24 3/16’’ (614) 24 3/16’’ (614)
L
Depth of cutout for flush control panel 26 5/8” (677) 26 5/8” (677) 26 5/8” (677)