INSTALLATION INSTRUCTIONS DishDrawerTM dishwasher DD24D 7 & DD24DT 7 models US CA 590204B 12.
1 FOLLOW THE INSTALLATION SEQUENCE RELEVANT TO YOUR MODEL 2 TALL HEIGHT DOUBLE MODELS STANDARD HEIGHT DOUBLE MODELS Classic Designer DD24DCX7 DD24DCW7 DD24DCB7 DD24DDFX7 PARTS SUPPLIED PARTS SUPPLIED PARTS SUPPLIED PARTS SUPPLIED PARTS SUPPLIED PARTS SUPPLIED OPTIONALLY HARD WIRING OPTIONALLY HARD WIRING OPTIONALLY HARD WIRING OPTIONALLY HARD WIRING OPTIONALLY HARD WIRING OPTIONALLY HARD WIRING PRODUCT & CABINETRY DIMENSIONS (STANDARD HEIGHT) PRODUCT & CABINETRY DIMENSIONS (STANDARD HEIG
2a SAFETY AND WARNINGS - ALL MODELS WARNING! Electrical hazard Before installing the dishwasher, remove the house fuse or open the circuit breaker. If permanently connecting the dishwasher, be sure the power is isolated and the dishwasher unplugged. GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
3a PARTS SUPPLIED - ALL MODELS Drain hose support (1) Moisture protection tape (1) (to prevent moisture damage) Drain hose joiner (1) Wire clip (2) (for securing Drain hose joiner) Hexagonal socket for feet adjustment (2) (long & short) Clamp (1) (for securing Drain hose joiner) Prefinished toekick (1) Side mounting bracket kit (A and B) (2) OPTIONAL Edge Protector (1) (If the services hole is through a metal partition the hole must be protected with the Edge protector supplied to prevent damage
4 5 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION 4a REMOVE THE LOWER DRAWER 4b REMOVE THE ACCESS COVER & POWER CORD 43 4 5 Access cover 1 6 8 To prevent kinked hoses, we recommend rotating the drawer anti-clockwise and resting 5 it on its side after removal. mm) 0m 41”0(100m 2 7 WARNING! Press the release tabs in on either side and push back to release drawer from runners. Electrical Shock Hazard Before continuing, ensure that the product is disconnected from the power supply.
5 PRODUCT DIMENSIONS 6 O K I Plan D C F A N Side G L O B E M H Product dimensions Integrated Classic Designer Integrated 32 5⁄16 - 34 5⁄8”(820-880)2 34 - 36 3⁄8”(864-924)2 34 - 36 3⁄8”(864-924)2 34 - 36 3⁄8”(864-924)2 23 9⁄16”(599) 23 9⁄16”(599) 23 9⁄16”(599) 23 9⁄16”(599) 22 ½”(571)3 22 15⁄16”(582) 22 ½”(571) 22 ½”(571)3 32 5⁄16 - 34 5⁄8”(820-880)2 32 5⁄16 - 34 5⁄8”(820-880)2 overall width of product 23 9⁄16”(599) 23 9⁄16”(599) overall depth of product (excl.
6 CABINETRY DIMENSIONS 7 Q Plan R S Side P Minimum clearances from adjacent cabinetry T Cabinetry dimensions TALL HEIGHT MODELS Designer Integrated Classic Designer Integrated inside height of cavity* STANDARD HEIGHT MODELS min. 1⁄16” (2 mm) clearance to adjacent cupboard door Classic P Q R S T inches (mm) min. ½” (13 mm) clearance from a corner cupboard min. 32 5⁄16”(820) min. 32 5⁄16”(820) min. 32 5⁄16”(820) min. 34”(864) min. 34”(864) min.
7a STANDARD HEIGHT INTEGRATED MODELS ONLY - CUSTOM PANEL CALCULATIONS FRONT PANEL SPECIFICATIONS The following calculations assume the top of the upper panel is aligned with the top of the adjacent cabinetry. The final panel/cabinetry alignment is achieved by adjusting the feet: 5⁄8 - 13⁄16” (16-20 mm) panel thickness Adequately sealed to withstand moisture (122OF/ 50OC @ 80% RH) Maximum weight of each panel: 20 lb (9 kg) WIDTH OF ALL PANELS A min.
7b TALL HEIGHT INTEGRATED MODELS ONLY - CUSTOM PANEL CALCULATIONS FRONT PANEL SPECIFICATIONS The following calculations assume the top of the upper panel is aligned with the top of the adjacent cabinetry. The final panel/cabinetry alignment is achieved by adjusting the feet: 5⁄8 - 13⁄16” (16-20 mm) panel thickness Adequately sealed to withstand moisture (122OF/ 50OC @ 80% RH) Maximum weight of each panel: 20 lb (9 kg) WIDTH OF ALL PANELS A min.
8 CAVITY PREPARATION COUNTERTOP 3⁄8” (10mm) Moisture protection tape must be applied. 10 Important! The power outlet must be located in a cabinet adjacent to the dishwasher cavity. 110-120 VAC max. 15 A Water Connection Recommended HOT (Maximum 140°F/60°C). Supplied hose to suit 3⁄8” (9 mm) male compression fitting. These marks indicate formed bracket screw locations, if securing by drawer removal. If there is no side partition, you can construct timber bracing as something to secure into.
9 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE Left hand side Drain hoses - 78 ½” (2000 mm) Inlet hose - 64 ¾” (1650 mm) Power cord (excl. plug) - 29 ½” (750 mm) 11 Right hand side Drain hoses - 70 ½” (1800 mm) Inlet hose - 49 ” (1250 mm) Power cord (excl.
NOW CHOOSE WHICH INSTALLATION METHOD (a) or (b) IS MORE SUITABLE FOR YOUR CABINETRY... RECOMMENDED METHOD (a) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) 11a PULL THROUGH HOSES & PUSH INTO THE CAVITY 10a ATTACH SIDE MOUNTING BRACKETS B Clip all four side mounting brackets into their slots using a flat-bladed screwdriver. Ensure they’re securely fitted before sliding product into cavity.
12a SECURE TO THE CABINETRY ON THE SIDES 13a OPTIONALLY SECURE TO THE CABINETRY ABOVE 1 (x2) Open the drawer halfway. Using a flat-bladed screwdriver, prize the gray rubber plug out of the trim moulding. 13 The top mounting brackets will only bend upwards a maximum of 3⁄8” (10 mm). Replace the gray rubber plug back into the trim moulding and ensure the trim seal is facing forward.
ALTERNATIVE METHOD (b) - SECURE BY DRAWER REMOVAL 10b PULL THROUGH HOSES & PUSH INTO THE CAVITY 11b REMOVE THE LOWER DRAWER To prevent kinked hoses, we recommend rotating the drawer counter-clockwise and resting it on its side after removal. (x2) optionally attach the two top mounting brackets 3 4 You can initially level the product 1 4 5 2 You can raise or lower the product by twisting the feet. Then take care when pushing the product into the cavity that you do not bend the feet.
12b SECURE TO THE CABINETRY ON THE SIDES To access the side brackets, you might have to push aside the insulation. After securing, ensure the sound insulation is repositioned correctly. For further adjustment, using the most appropriate length Hexagonal socket supplied, fully extend leveling feet up to required distance by hand. (x2) Secure using two pairs of formed brackets (use 5⁄8” (16 mm) screws). Repeat on the other side of the chassis.
15b FIT THE SUPPLIED TOEKICK PANEL (OPTIONAL FOR INTEGRATED MODELS) 1 Where the toekick meets the bottom of the tub is the cut-off point 3 17 5 7 Mounting rail 19 9 Lay the toekick face down on a chopping board or similiar 4 Turn the toekick over and score along the same line 6 Smooth the edge with a file. Be careful of sharp edges.
INTEGRATED MODELS ONLY - INSTALLING THE FRONT PANELS 16 REMOVE BRACKETS FROM PRODUCT 17 ATTACH PANELS TO PANEL BRACKETS 2 WARNING! Electrical Shock Hazard 18 1 There must be at least 3 screws used each side 5⁄8” (16mm) x6 16 mm x6 Before continuing, ensure that the product is disconnected from the power supply. Failure to follow this warning may result in electrical shock, injury or fire. Important! Break off and discard the tab at the top of the Lower Panel Bracket.
INTEGRATED MODELS ONLY - INSTALLING THE FRONT PANELS 20 ADJUST PANEL HEIGHT TO ALIGN THE CABINETRY GAPS 21 FITTING A CUSTOM TOEKICK PANEL 16 x5 x5 5⁄8” mm (16mm) + or - 1⁄16” (2 mm) With the front panels fitted, insert an appropriately sized Philips screwdriver into the hole above the door pin and rotate the panels up or down to align the gaps in your cabinetry. Repeat on the other side if necessary. Each panel has a maximum travel of 1⁄16” (2 mm) up or down.
22 THERE ARE THREE DIFFERENT DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE. If space is limited for fixing, push hose through drain hose support to required height Dishwasher using Air Break with Drain Hose Joiner If space is limited for fixing, push hose through drain hose support to required height 2 Supplied drain hose joiner Ø ¾” (19 mm) waste tee 750-882.5 29 ½”-34 ¾”mm (750-882.5 mm) 2 max. max.
25 FINAL CHECKLIST 26 TROUBLESHOOTING Check all parts are installed. Ensure product is level, securely fastened to the cabinetry and opens and closes freely. The drawers must be free to fully close with no resistance from the cabinetry. Ensure inlet hose to water supply has supplied rubber washer fitted, and that it’s tightened a further half turn after seal contact. Ensure any knockouts or plugs in drain connection have been drilled out and drain connection has been made.