Installation Guide

8
7 CAVITY PREPARATION
Water Connection
Recommended HOT
(Maximum 140°F/60°C).
Supplied hose to suit
3/8” (9 mm) male
compression fitting.
Water Pressure
Water softener models
Max. 1 MPa (145 psi)
Min. 0.1 MPa (14.5 psi)
Models without
water softener
Max. 1 MPa (145 psi)
Min. 0.03 MPa (4.3 psi)
IMPORTANT!
The power outlet must be
located in a cabinet adjacent
to the dishwasher cavity.
110-120 VAC max. 15 A
min. 7 7/8” (200 mm)
Service Holes
Service holes can be located either side of dishwasher, close to the rear
face and the shelf, as illustrated.
O
If the hole is through wood, make sure its edges are smooth androunded.
O
If the hole is through metal, ensure you fit the supplied Edge Protector to
prevent damage to the power cord.
These marks indicate formed
bracket screw locations, if
securing by drawer removal.
If there is no side partition, you
can construct timber bracing
as something to secure into.
Moisture
protection tape
must be applied
3/8”
(10 mm)
COUNTERTOP
WARNING!
Incorrect placement of the hole
will result in damage to hoses.
Service hole –
see Section 8
fordetail
Max 1/2” (10mm)
Max distance between
hole edge and shelf
Max 1/4” (5mm)
Max distance
between hole edge
and rear inner face
max. 17 11/16”