Installation Guide

8
PLUMBING & ELECTRICAL CONSIDERATIONS
SERVICE DIMENSION
LEFT SIDE* RIGHT SIDE*
INCHES MM INCHES MM
A Length of drain hoses 78 1/2 2000 70 1/2 2000
B Length of power cord** 64 3/4 1650 64 3/4 1650
C Length of inlet hose 64 3/4 1650 49 1650
D Distance from floor to top of
hose support
29 1/2 – 
34 3/4
750 – 883
29 1/2 – 
34 3/4
750 – 883
E Minimum distance from floor to end
of drain hoses***
19 11/16 500 19 11/16 500
F Minimum distance from floor to inlet
hose connection
7 7/8 200 7 7/8 200
G Maximum distance from cabinetry
centre of electrical outlet
17 11/16 450 17 11/16 450
H Maximum distance from floor to top
of Air Break
37 3/8 950 37 3/8 950
*dimensions taken from the chassis edge where applicable
**excluding plug
***standpipe install illustrated. Distance is the same for sink trap installations.
Hose and cord lengths
z
Your services can be installed to either the left-hand or right-hand side
of the product in an adjacent cabinet. Refer to ‘Preparation’ for service
access requirements.
z
If the drain hoses supplied are not long enough to reach your services,
you may purchase a Fisher & Paykel drain hose extension kit which will
extend the drain hoses by 3.6m (part number 525798).
Water connection
z
Recommended water temperature: Hot (Maximum 140°F/60°C).
z
Supplied hose to suit 3/8" (9 mm) male compression fitting.
z
Ensure water connection complies with local plumbing regulations.
Water pressure
z
Water softener models: max. 1 MPa (145 psi), min. 0.1 MPa (14.5 psi)
z
Non-water softener models: max. 1 MPa (145 psi), min. 0.03 MPa (4.3 psi)
Electrical requirements
z
110-120 VAC max. 15A
Kosher requirements
z
Drains will need to be separated to satisfy kosher requirements.
z
We recommend confirming the acceptability with your local rabbi in
respect to kosherinstallations.