DOUBLE DISHDRAWER™ DISHWASHER DD60DDF models INSTALLATION GUIDE NZ AU GB IE SG 591384C 05.
1 ! SAFETY AND WARNINGS Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the circuit breaker. This appliance must be earthed. In the event of a malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-earthing conductor and an earthing plug.
2 Drain hose support (1) Phillips 16 mm screws (9) Drain hose joiner (1) Rubber washer for inlet hose (1) (comes already fitted) PARTS SUPPLIED Wire clip (2) (for securing Drain hose joiner) Moisture protection tape (1) (to prevent moisture damage to cabinetry) Clamp (1) (for securing Drain hose joiner) Side mounting bracket kit (A and B) (2) OPTIONAL Hexagonal socket for feet adjustment (2) (long & short) Prefinished toekick (1) Top mounting brackets (2) OPTIONAL Dishdrawer™ installation overv
3 PRODUCT DIMENSIONS C J H K G F A I L FRONT M PROFILE N DD60DDF B PRODUCT DIMENSIONS A D MM Overall height of product1 820-8802 B Overall width of product 599 C Overall depth of product 573 D Depth of chassis (to back of front drawer panel) 553 E Depth of drawer front panel 20 F 811 Height of chassis1 G Height of drawer front panels E O H Height of upper drawer front panel 398 I Height of lower drawer front panel 312 J Height from top of drawer front panel to top of chas
4 CABINETRY DIMENSIONS Q S P R Bracket slots T PLAN PROFILE DD60DDF CABINETRY DIMENSIONS P Inside height of cavity* MM min. 820 Q Inside width of cavity 600 R Inside depth of cavity min. 560 S Recommended height of adjacent cabinet space T Height of toekick space* Minimum clearances from adjacent cabinetry 720 100-160 * depending on adjustment of levelling feet min. 13 mm clearance from a corner cupboard min.
5 CAVITY PREPARATION COUNTERTOP Water Connection Recommended COLD (Maximum 60°C). 10 mm Moisture protection tape must be applied. 3/4“ BSP (GB20) to suit flat washer. Water Pressure Water softener models Max. 1 MPa (145 psi) Min. 0.1 MPa (14.5 psi) These marks indicate formed bracket screw locations, if securing by drawer removal. Models without water softener Max. 1 MPa (145 psi) Min. 0.03 MPa (4.3 psi) If there is no side partition, you can construct timber bracing as something to secure into.
6 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE LEFT HAND SIDE Drain hoses — 2000mm Inlet hose — 1650mm Power cord (excl.plug) — 1650mm RIGHT HAND SIDE Drain hoses — 1800mm Inlet hose — 1250mm Power cord (excl.
NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITABLE FOR YOUR CABINETRY... 7 RECOMMENDED METHOD (A) — SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) 8-A B ATTACH SIDE MOUNTING BRACKETS Clip all four side mounting brackets into their slots using a flat-bladed screwdriver. Ensure they’re securely fitted before sliding product into cavity.
!0-A SECURE TO THE CABINETRY ON THE SIDES !1-A OPTIONALLY SECURE TO THE CABINETRY ABOVE 1 (x2) Open the drawer halfway. Using a flat bladed screwdriver, prise the grey rubber plug out of the trim moulding. The top mounting brackets will only bend upwards a maximum of 10 mm. Replace the grey rubber plug back into the trim moulding and ensure the trim seal is facing forward. 3 2 Using a small Philips screwdriver, screw through the trim moulding, securing the side mounting bracket to the cabinetry.
7 8-B ALTERNATIVE METHOD (B) — SECURE BY DRAWER REMOVAL 9-B PULL THROUGH HOSES & PUSH INTO THE CAVITY optionally attach the two top mounting brackets (x2) REMOVE THE LOWER DRAWER To prevent kinked hoses Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal. When fitting brackets, ensure the ends are not pushed down into the chassis.
!0-B !1-B SECURE TO THE CABINETRY ON THE SIDES OPTIONALLY SECURE TO THE CABINETRY ABOVE (x2) For further adjustment, using the most appropriate length Hexagonal socket supplied, fully extend levelling feet up to required distance by hand. The top mounting brackets will only bend upwards a maximum of 10 mm. Secure using two pairs of formed brackets. Repeat on the other side of the chassis. x4 Hexagonal socket Ensure product is level and aligning with cabinetry.
!3 Where the toekick meets the bottom of the tub is the cut-off point 3 FIT THE SUPPLIED TOEKICK PANEL 5 19 1 Lay the toekick face down on a chopping board or similiar 2 Mounting rail 7 4 Turn the toekick over and score along the same line 6 Smooth the edges with a file. Be careful of sharp edges.
THERE ARE TWO DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE. DRAINAGE OPTION 1 Dishwasher and 38 mm Standpipe DRAINAGE OPTION 2 Dishwasher using drain hose joiner onto sink trap/waste tee Screw Drain hose support to back wall at correct height. If space is limited for fixing, push hose through drain hose support to required height. If space is limited for fixing, push hose through drain hose support to required height. 2 3 1 step 15 min.
!5 CONNECT INLET HOSE TO COLD WATER !6 PLUG PRODUCT IN min. 10mm 3/4” BSP connector 180o No leaks! Ensure the supplied rubber washer is fitted inside the coupling. Tighten coupling with spanner. 1 2 !7 TROUBLESHOOTING O Excessive water remaining above the filter plate, after the rinse cycle. (This is displayed as an A3 fault.
!8 FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER Check all parts are installed. Ensure that all panels and parts thereof are secure and final electrical tests have been conducted in accordance with local electrical regulations. Turn on the power and water supplies, then open the drawers. You should hear a beep and see a program indicator light up on the control panel. Check the spray arms are in place, mounted correctly and free to rotate, by physically rotating by hand.
SINGLE DISHDRAWER™ DISHWASHER DD60SDF models INSTALLATION GUIDE NZ AU GB IE SG 591384C 05.
1 ! SAFETY AND WARNINGS Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the circuit breaker. This appliance must be earthed. In the event of a malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-earthing conductor and an earthing plug.
2 Drain hose support (1) Phillips 16 mm screws (7) Drain hose joiner (1) 38 mm bottom fixing screws & metal washers (2) Wire clip (1) (for securing Drain hose joiner) Rubber washer for inlet hose (1) (comes already fitted) PARTS SUPPLIED Clamp (1) (for securing Drain hose joiner) Moisture protection tape (1) (to prevent moisture damage to cabinetry) Side mounting bracket kit (A and B) (2) OPTIONAL Top mounting brackets (2) OPTIONAL Cavity Bracket Kit (1) (supplied with Tall Height Models only)
3 PRODUCT DIMENSIONS C H F G A FRONT I PROFILE B D E STANDARD HEIGHT TALL HEIGHT DD60SDF DD60SDFT MM MM A Overall height of product 410 4782 B Overall width of product 599 599 C 573 573 553 553 E Depth of drawer front panel 20 20 F Height of drawer front panel 398 470 G Height of chassis 410 454 2 24 8 8 547 547 PRODUCT DIMENSIONS 1 Overall depth of product D Depth of chassis (to back of front drawer panel) 1 j H Height from top of drawer front panel to top
4 CABINETRY DIMENSIONS Q K R Bracket slots PLAN STANDARD HEIGHT TALL HEIGHT DD60SDF DD60SDFT MM MM min. 412 480 L Inside width of cavity 600 600 M Inside depth of cavity min. 560 min. 560 CABINETRY DIMENSIONS K Inside height of cavity PROFILE Minimum clearances from adjacent cabinetry Cavity height options allow you to match dishwasher with your cabinetry or companion products DD60SDF (Standard height models) K min.
5 CAVITY PREPARATION COUNTERTOP 10 mm Moisture protection tape must be applied. Water Connection Recommended COLD (Maximum 60°C). These marks indicate formed bracket screw locations, if securing by drawer removal. 3/4“ BSP (GB20) to suit flat washer. If there is no side partition, you can construct timber bracing as something to secure into. Ø 57mm Water Pressure Water softener models Max. 1 MPa (145 psi) Min. 0.1 MPa (14.5 psi) max. 450mm WARNING! Models without water softener Max.
6 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE LEFT HAND SIDE RIGHT HAND SIDE Drain hoses — 1800mm Drain hose — 2000mm Inlet hose — 1250 mm Inlet hose — 1650mm Power cord (excl.plug) — 2000mm 6 Power cord (excl.plug) — 2000mm TALL HEIGHT DESIGNER MODELS FOR 480 MM CAVITY ONLY — ATTACH CAVITY BRACKET IMPORTANT! The enclosed cavity bracket is fitted before installation in order to conceal the gap at the top of the cavity left after installation.
NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITABLE FOR YOUR CABINETRY... 7 RECOMMENDED METHOD (A) — SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) 8-A B ATTACH SIDE MOUNTING BRACKETS Clip all four side mounting brackets into their slots using a flat-bladed screwdriver. Ensure they’re securely fitted before sliding product into cavity. B 9-A PULL THROUGH HOSES & PUSH INTO THE CAVITY A A A B B A The mounting slots are in pairs, one on each side diagonally across the product.
!0-A SECURE TO THE CABINETRY ON THE SIDES 1 Using a small Philips screwdriver, screw through the trim moulding, securing the side mounting bracket to the cabinetry. Do not damage the rubber trimseal. Open the drawer halfway. Using a flat bladed screwdriver, prise the grey rubber plug out of the trim moulding. 3 2 Replace the grey rubber plug back into the trim moulding and ensure the trim seal is facing forward. Repeat for all four brackets.
7 8-B ALTERNATIVE METHOD (B) — SECURE BY DRAWER REMOVAL PULL THROUGH HOSES & PUSH INTO THE CAVITY 9-B REMOVE THE LOWER DRAWER To prevent kinked hoses Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal. 1 3 2 4 Sit the drawer down As you push product in, pull through hoses and cord, ensuring they don’t get kinked or twisted. 3 100 Push drawer runners back in on either side.
!0-B SECURE TO THE CABINETRY ON THE SIDES The product has three pairs of fixing points: Ensure the sound insulation is repositioned correctly. 2 two pairs of formed brackets on either side of the chassis (use 16 mm screws) a pair of fixing holes either side on the bottom (use 38 mm fixing screws & washers) 1 !1-B REFIT THE DRAWER ONTO THE RUNNERS 2 Lift or rotate anti-clockwise the drawer back onto the drawer runners on either side.
THERE ARE TWO DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE. DRAINAGE OPTION 2 Dishwasher using drain hose joiner onto sink trap/waste tee DRAINAGE OPTION 1 Dishwasher and Ø 38 mm Standpipe Screw Drain hose support to back wall at correct height. 2 If space is limited for fixing, push hose through drain hose support to required height. 750-883 mm If space is limited for fixing, push hose through drain hose support to required height.
!3 CONNECT INLET HOSE TO COLD WATER !4 PLUG PRODUCT IN min. 10mm 3/4” BSP connector 180o No leaks! Ensure the supplied rubber washer is fitted inside the coupling. 2 1 Tighten coupling with spanner.
!5 TROUBLESHOOTING O Excessive water remaining above the filter plate, after the rinse cycle. (This is displayed as an A3 fault. See user guide ‘How to attend to a fault’) Check for a kinked drain hose, blocked or incorrectly drilled out waste connection, highloop not properly installed, drain hose not routed correctly or spray arm not in place. O No water supply. (This is displayed as an A1 fault. See user guide ‘How to attend to a fault’) Check water is connected and turned on.
!6 FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER Check all parts are installed. Ensure that all panels and parts thereof are secure and final electrical tests have been conducted in accordance with local electrical regulations. Turn on the power and water supplies, then open the drawer. You should hear a beep and see a program indicator light up on the control panel. Check the spray arms are in place, mounted correctly and free to rotate, by physically rotating by hand.