INSTALLATION INSTRUCTIONS DishDrawerTM dishwasher DD60S 7 & DD60ST 7 models NZ AU GB IE 590200C 12.
1 FOLLOW THE INSTALLATION SEQUENCE RELEVANT TO YOUR MODEL TALL HEIGHT SINGLE MODELS STANDARD HEIGHT SINGLE MODELS ONLY AVAILABLE IN NZ AU Classic Designer Integrated with remote control DD60SC(H)X7 DD60SC(H)W7 DD60SC(H)B7 DD60SCM7 DD60SDF(H)X7 DD60SDFM7 DD60SI7 PARTS SUPPLIED PARTS SUPPLIED PRODUCT & CABINETRY DIMENSIONS (STANDARD HEIGHT) PRODUCT & CABINETRY DIMENSIONS (STANDARD HEIGHT) CAVITY PREPARATION CAVITY PREPARATION MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE MAXIMUM DISTANCE OF
2a SAFETY AND WARNINGS - ALL MODELS WARNING! Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the circuit breaker. This appliance must be earthed. In the event of a malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-earthing conductor and an earthing plug.
3a PARTS SUPPLIED - ALL MODELS Drain hose support (1) Drain hose joiner (1) Wire clip (1) (for securing Drain hose joiner) Side mounting bracket kit (A and B) (2) OPTIONAL Clamp (1) (for securing Drain hose joiner) Phillips 16 mm screws (7) 38 mm bottom fixing screws & metal washers (2) Cavity bracket kit (1) supplied with Tall height Designer and Integrated models only If the Drain hose supplied is not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which
3b ADDITIONAL PARTS SUPPLIED WITH INTEGRATED MODELS External Venting kit (1) supplied with Integrated models with remote (NZ AU) only Panel bracket (1) (attached to product) Panel mounting screws (6) Integrated rectangular badge (1) (Satin chrome supplied) supplied with Integrated models with badge (GB IE) only
4 PRODUCT DIMENSIONS 6 K H A I Plan G Side D C F J B E Product dimensions Integrated Badge control 480 mm cavity Integrated Remote control 480 mm cavity Integrated Badge control Designer 456 mm cavity Classic Integrated Remote control Integrated Badge control 456 mm cavity Integrated Remote control overall height1 of product (incl.
5 CABINETRY DIMENSIONS 7 M L Cabinetry dimensions STANDARD HEIGHT MODELS TALL HEIGHT MODELS Integrated Badge control 480 mm cavity Integrated Remote control 480 mm cavity min. 412 min. 412 min. 412 456 480 456 456 480 480 600 600 600 600 600 600 600 600 600 600 inside depth of cavity min. 560 min. 560 min. 560 min. 560 min. 560 min. 560 min. 560 min. 560 min. 560 min.
6a INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY - CUSTOM FRONT PANEL CALCULATIONS 8 min. 2 mm FRONT PANEL SPECIFICATIONS 16 -20 mm panel thickness Adequately sealed to withstand moisture (50OC @ 80% RH) Maximum weight of panel: 9 kg The following calculations assume the top of the panel is aligned with the top of the adjacent cabinetry: A min. 2 mm min. 2 mm WIDTH OF THE PANEL Measure A (the width between adjacent door/drawer fronts) and write it in the first box below, then complete the equation.
6b INTEGRATED MODELS WITH BADGE (GB IE) ONLY - CUSTOM FRONT PANEL CALCULATIONS 9 min. 2 mm FRONT PANEL SPECIFICATIONS 16 -20 mm panel thickness Adequately sealed to withstand moisture (50OC @ 80% RH) Maximum weight of panel: 9 kg The following calculations assume the top of the panel is aligned with the top of the adjacent cabinetry: A min. 2 mm min. 2 mm WIDTH OF THE PANEL Measure A (the width between adjacent door/drawer fronts) and write it in the first box below, then complete the equation.
7a CAVITY PREPARATION Important! BENCHTOP The power outlet must be located in a cabinet adjacent to the dishwasher cavity. Moisture 10 mm protection tape must be applied. 220-240 VAC min. 4.8 A Water Connection Recommended COLD (Maximum 60°C). ¾ “ BSP (GB20) to suit flat washer. These marks indicate formed bracket screw locations, if securing by drawer removal. Important! Water Pressure Services can be located either side of the dishwasher. Water softener models Max. 1 MPa (145 psi) Min. 0.
7b INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY - PREPARATION FOR EXTERNAL VENTING THROUGH SAME CABINET Services can be located either side of dishwasher External Venting kit (1) Shelf cutouts max.
8 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE Left hand side Drain hose - 2000 2000 mm mm Inlet Inlet hose hose--1650 1650mm mm Power cord cord (excl. (excl. plug) plug) - 1650 1650 mm mm Venting hose - 1525 mm (Integrated (Integratedmodels wirelesswith models only) remote (NZ AU) only) 12 Right hand side Drain hose hose -- 1800 1800 mm mm Inlet hose - 1250 mm mm Power cord (excl.
9 TALL HEIGHT DESIGNER & INTEGRATED MODELS FOR 480 mm CAVITY ONLY - ATTACH CAVITY BRACKET The enclosed cavity bracket is fitted before installation in order to conceal the gap at the top of the cavity left after installation. 1 2 Firmly push the bracket so that the prongs engage with the top tabs and it clicks into place. 1 Important! Ensure the prongs have not been driven down into the chassis as this will damage the lid below.
NOW CHOOSE WHICH INSTALLATION METHOD (a) or (b) IS MORE SUITABLE FOR YOUR CABINETRY... RECOMMENDED METHOD (a) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) 10a ATTACH SIDE MOUNTING BRACKETS Clip all four side mounting brackets into their slots using a flat-bladed screwdriver. Ensure they’re securely fitted before sliding product into cavity.
12a PULL THROUGH HOSES & MOVE INTO THE CAVITY 15 13a SECURE THE DRAWER 1 Vent Hose (Integrated models with remote (NZAU) only) Open the drawer halfway. Using a flat-bladed screwdriver, prise the grey rubber plug out of the trim moulding. Replace the grey rubber plug back into the trim moulding and ensure the trim seal is facing forward.
ALTERNATIVE METHOD (b) - SECURE BY DRAWER REMOVAL 10b INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY ATTACH VENTING HOSE Check that the fitted elbow is rotated left or right (depending on the direction of the routing), then ensure the venting hose is securely attached to it.
12b REMOVE THE DRAWER 13b SECURE THE DRAWER TO THE CABINETRY 4 1 17 The product has three pairs of fixing points: Product may move. Mark chassis position on cavity Ensure the sound insulation is repositioned correctly. To prevent kinked hoses, we recommend rotating the drawer anti-clockwise and resting it on its side after removal.
INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY - INSTALLING THE FRONT PANEL 16a REMOVE BRACKET FROM PRODUCT 17a ATTACH PANEL TO PANEL BRACKET WARNING! Electrical Shock Hazard There must be at least 3 screws used each side Before continuing, ensure that the product is disconnected from the power supply. Failure to follow this warning may result in electrical shock, injury or fire.
INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY - INSTALLING THE FRONT PANEL 20a ADJUST PANEL HEIGHT TO ALIGN THE CABINETRY GAPS With the front panel fitted, insert an appropriately sized Philips screwdriver into the hole above the door pin and rotate the panel up or down to align the gaps in your cabinetry. Repeat on the other side if necessary. + or - 2 mm The panel has a maximum travel of 2 mm up or down. Important! Ensure that you maintain a minimum of 2 mm ventilation gap below the panel.
INTEGRATED MODELS WITH BADGE (GB IE) ONLY - INSTALLING THE FRONT PANEL & BADGE CONTROLS 16b DETERMINE BADGE CUTOUT LOCATION 20 17b REMOVE BRACKET & DISCONNECT BADGE WARNING! Electrical Shock Hazard Before continuing, ensure that the product is disconnected from the power supply. 228.5 mm Failure to follow this warning may result in electrical shock, injury or fire. 228.
INTEGRATED MODELS WITH BADGE (GB IE) ONLY - INSTALLING THE FRONT PANEL & BADGE CONTROLS 20b REATTACH BADGE & EARTH THE PANEL 21b ATTACH PANEL TO PRODUCT WARNING! Ensure the rubber seal between the drawer and panels is kept in place. Electrical Shock Hazard Connect the integrated badge earth wire to one of the two tabs provided on the panel bracket. To earth the panel bracket, connect the earth wire from the product to the other tab. Any custom metal component (e.g.
23 THERE ARE TWO DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE. Dishwasher using sink trap with drain hose joiner 38 mm If space is limited for fixing, push hose through drain hose support to required height 3 2 2 1 HIGHLOOP min. 150 mm max. 120 mm Supplied drain hose joiner 19 mm waste tee 750-882.5 mm If space is limited for fixing, push hose through drain hose support to required height 1 see 24* 750 - 882.5 mm see 24* 750 - 882.5 mm 750-882.
26 FINAL CHECKLIST 27 TROUBLESHOOTING Check all parts are installed. Ensure that all panels and parts thereof are secure and final electrical tests have been conducted in accordance with local electrical regulations. Ensure product is level, securely fastened to the cabinetry and opens and closes freely. The drawer must be free to fully close with no resistance from the cabinetry.