DOUBLE DISHDRAWER TM DISHWASHER DD60DI & DD60DHI models INSTALLATION GUIDE NZ AU GB IE 591383 A 08.
1
1 ! SAFETY AND WARNINGS WARNING! Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the circuit breaker. This appliance must be earthed. In the event of a malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-earthing conductor and an earthing plug.
1 SAFETY AND WARNINGS IMPORTANT SAFETY INSTRUCTIONS ● ● ● ● ● ● ● ● ● ● ● ● ● Installation of this dishwasher requires basic mechanical and electrical skills. Be sure to leave these Instructions with the Customer. Installation must comply with your local building and electricity regulations. At the completion of the dishwasher installation, the Installer must perform the Final Checklist. Remove all packaging materials supplied with the dishwasher.
2 Drain hose support (1) Phillips 16 mm screws (9) Drain hose joiner (1) Wire clip (2) (for securing Drain hose joiner) Rubber washer for inlet hose (1) (comes already fitted) Panel bracket (2) & Knock-to-Pause Module (2) (shipped fixed to product) PARTS SUPPLIED Panel mounting screws (12) Moisture protection tape (1) (to prevent moisture damage to cabinetry) Clamp (1) (for securing Drain hose joiner) Side mounting bracket kit (A and B) (2) OPTIONAL Hexagonal socket for feet adjustment (2) (long
3 PRODUCT DIMENSIONS C H G A J F I K FRONT PROFILE L M PRODUCT DIMENSIONS B D E MM A Overall height of product B Overall width of product C Overall depth of product D Depth of chassis (to back of front drawer panel) E Depth of drawer front panel F Height of chassis G Height of drawer front panels H Height of upper drawer front panel min.
4 CABINETRY DIMENSIONS P R O Q S Bracket slots PLAN PROFILE DD60DI DD60DHI CABINETRY DIMENSIONS O Inside height of cavity* MM min. 820 P Inside width of cavity 600 Q Inside depth of cavity min. 560 R Recommended height of adjacent cabinet space S Height of toekick space* Minimum clearances from adjacent cabinetry 720 100-160 * depending on adjustment of levelling feet min. 13 mm clearance from a corner cupboard min.
5 CUSTOM DRAWER PANEL CALCULATIONS FRONT PANEL MATERIAL SPECIFICATIONS ● ● ● ● ● 16 - 20mm panel thickness Adequately sealed to withstand moisture (50OC @ 80% RH) Because of it being a hot and wet environment generally, the back and sides of the panel should be completely sealed with a waterproof vapour barrier (ie polyurethane) to prevent damage to the panel.
6 CUSTOM TOEKICK PANEL CALCULATIONS TOEKICK PANEL MATERIAL SPECIFICATIONS min. 9mm panel thickness if using supplied screws Adequately sealed to withstand moisture (50OC @ 80% RH) You may choose to affix your custom toekick panel either by screwing it or gluing it to the supplied mounting bracket. ● ● ● HEIGHT OF THE TOEKICK PANEL Measure D (height from the top of adjacent cabinet door fronts to the floor) and write it in the first box below, then complete the equation.
7 BENCHTOP 10 mm Moisture protection tape must be applied. CAVITY PREPARATION IMPORTANT! The power outlet must be located in a cabinet adjacent to the dishwasher cavity. 220-240 VAC min. 9.5 A Water Connection Recommended COLD (Maximum 60°C). 3/4“ BSP (GB20) to suit flat washer. Water Pressure These marks indicate formed bracket screw locations, if securing by drawer removal. Water softener models Max. 1 MPa (145 psi) Min. 0.1 MPa (14.5 psi) Models without water softener Max. 1 MPa (145 psi) Min. 0.
8 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE LEFT HAND SIDE Drain hoses - 2000mm Inlet hose - 1650mm Power cord (excl.plug) - 1650mm RIGHT HAND SIDE Drain hoses - 1800mm Inlet hose - 1250mm Power cord (excl.
NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITABLE FOR YOUR CABINETRY... 9 RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) 9-A B ATTACH SIDE MOUNTING BRACKETS Clip all four side mounting brackets into their slots using a flat-bladed screwdriver. Ensure they’re securely fitted before sliding product into cavity.
!1-A SECURE TO THE CABINETRY ON THE SIDES !2-A OPTIONALLY SECURE TO THE CABINETRY ABOVE 1 Open the drawer halfway. Using a flat bladed screwdriver, prise the grey rubber plug out of the trim moulding. (x2) The top mounting brackets will only bend upwards a maximum of 10mm. Replace the grey rubber plug back into the trim moulding and ensure the trim seal is facing forward. 3 2 Using a small Philips screwdriver, screw through the trim moulding, securing the side mounting bracket to the cabinetry.
9 9-B ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVAL !0-B PULL THROUGH HOSES & PUSH INTO THE CAVITY optionally attach the two top mounting brackets (x2) REMOVE THE LOWER DRAWER To prevent kinked hoses Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal. When fitting brackets, ensure the ends are not pushed down into the chassis.
!1-B !2-B SECURE TO THE CABINETRY ON THE SIDES OPTIONALLY SECURE TO THE CABINETRY ABOVE (x2) For further adjustment, using the most appropriate length Hexagonal socket supplied, fully extend levelling feet up to required distance by hand. The top mounting brackets will only bend upwards a maximum of 10 mm. Secure using two pairs of formed brackets. Repeat on the other side of the chassis. x4 Hexagonal socket Ensure product is level and aligning with cabinetry.
!4 !4-A INSTALLING CUSTOM FRONT DRAWER PANELS REMOVE BOTH PANEL BRACKETS FROM PRODUCT !4-B REMOVE THE KNOCK-TO-PAUSE MODULE WARNING! Electrical Shock Hazard Before continuing, ensure that the product is disconnected from the power supply. Failure to follow this warning may result in electrical shock, injury or fire. Knock-to-Pause module 1 1 Side Pin 2 1 1 Remove side pins and gently pull off the panel bracket slightly. Repeat for the other drawer.
!4 !4-C INSTALLING CUSTOM FRONT DRAWER PANELS !4-D ATTACH CUSTOM PANELS TO PANEL BRACKETS 3 2 ATTACH KNOCK-TO-PAUSE MODULES TO CUSTOM PANELS x6) m( 16m 1 There must be at least 3 screws used each side. 1 2 Align bottom of each custom panel with the bottom of each bracket. 16mm (x3) IMPORTANT! 4 ● ● IMPORTANT! Break off and discard the tab at the top of the Lower Panel Bracket. Ensure the Knock-To-Pause module is orientated correctly before attaching.
!4 !4-E INSTALLING CUSTOM FRONT DRAWER PANELS CONNECT THE KNOCK-TO-PAUSE MODULE TO THE CONTROLLER !4-F RECONNECT THE EARTH WIRE TO THE PANEL BRACKET WARNING! Electrical Shock Hazard To earth the panel bracket, connect the earth wire from the product to one of the tabs. Any custom metal component (e.g. handle) that extends past the rubber seal must be earthed too. Failure to follow these warnings may result in electrical shock, injury or fire. Controller Reconnect the Earth Wire to the Panel bracket.
!5 FITTING A CUSTOM TOEKICK PANEL Custom Toekick Panel 2 Place the Toekick panel cutting template onto your toekick panel. Ensure they are centered and the template rests on the top surface of the panel. 3 Secure template to panel either by clamping or using the supplied mounting screws.
!6 FIT THE SUPPLIED PREFINISHED TOEKICK PANEL (IF PREFERRED) Prefinished Toekick Panel 3 3 Where the toekick meets the bottom of the tub is the cut-off point 11 77 19 Lay the toekick face down on a chopping board or similiar 4 4 2 2 5 5 Turn the toekick over and score along the same line Smooth the edge with a file. Be careful of sharp edges.
THERE ARE TWO DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE. Dishwasher using drain hose joiner onto sink trap/waste tee Dishwasher and Ø 38 mm Standpipe If space is limited for fixing, push hose through drain hose support to required height 2 max. 120 mm 3 step 16 step 16 min. radius 200 mm 750 - 882.5 mm 38 mm min. 500 mm 1 750 - 882.5 mm 1 min. 500 mm 2 max. 120 mm Supplied drain hose joiner to suit 19 mm waste tee 750-882.
!6 CONNECT INLET HOSE TO COLD WATER !7 PLUG PRODUCT IN min. 10mm 3/4” BSP connector 180o No leaks! Ensure the supplied rubber washer is fitted inside the coupling. Tighten coupling with spanner. 1 2 !8 TROUBLESHOOTING ● Excessive water remaining above the filter plate, after the rinse cycle. (This is displayed as an A3 fault.
!9 FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER Check all parts are installed. Ensure that all panels and parts thereof are secure and final electrical tests have been conducted in accordance with local electrical regulations. Turn on the power and water supplies, then open the drawers. You should hear a beep and see a program indicator light up on the control panel. Check the spray arms are in place, mounted correctly and free to rotate, by physically rotating by hand.
SINGLE DISHDRAWER TM DISHWASHER DD60SI, DD60STI, DD60SLI, DD60SHI & DD60SHTI models INSTALLATION GUIDE NZ AU GB IE 591383 A 08.
1
1 ! SAFETY AND WARNINGS WARNING! Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the circuit breaker. This appliance must be earthed. In the event of a malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-earthing conductor and an earthing plug.
1 SAFETY AND WARNINGS IMPORTANT SAFETY INSTRUCTIONS ● ● ● ● ● ● ● ● ● ● ● ● ● Installation of this dishwasher requires basic mechanical and electrical skills. Be sure to leave these Instructions with the Customer. Installation must comply with your local building and electricity regulations. At the completion of the dishwasher installation, the Installer must perform the Final Checklist. Remove all packaging materials supplied with the dishwasher.
2 Drain hose support (1) Phillips 16 mm screws (7) Drain hose joiner (1) 38 mm bottom fixing screws & metal washers (2) Panel bracket (1) & Knock-to-Pause Module (1) (shipped fixed to product) PARTS SUPPLIED Wire clip (1) (for securing Drain hose joiner) Rubber washer for inlet hose (1) (comes already fitted) Panel mounting screws (6) Clamp (1) (for securing Drain hose joiner) Moisture protection tape (1) (to prevent moisture damage to cabinetry) Side mounting bracket kit (A and B) (2) OPTIONAL
3 PRODUCT DIMENSIONS B C F A G H FRONT PROFILE STANDARD HEIGHT STANDARD HEIGHT DD60SLI DD60SI DD60SHI DD60STI DD60SHTI DD60STI DD60SHTI MM MM MM MM 410 410 454 599 599 599 599 571 571 571 571 553 553 553 553 E Depth of drawer front panel 16-20 16-20 16-20 16-20 F Height of drawer front panel min.
4 CABINETRY DIMENSIONS Cavity Bracket (480mm cavity height) Custom Filler Panel (other heights) K P J L Q Bracket slots PLAN STANDARD HEIGHT TALL HEIGHT (Installed in a 456mm high cavity) TALL HEIGHT (Installed in a 480mm high cavity) DD60SI DD60SHI DD60SLI DD60STI DD60SHTI DD60STI DD60SHTI MM MM MM min. 412 456 480 K Inside width of cavity 600 600 600 L Inside depth of cavity min. 560 min. 560 min.
5 CUSTOM DRAWER PANEL CALCULATIONS FRONT PANEL MATERIAL SPECIFICATIONS ● ● ● ● ● min. 2mm 16 - 20mm panel thickness Adequately sealed to withstand moisture (50OC @ 80% RH) Because of it being a hot and wet environment generally, the back and sides of the panel should be completely sealed with a waterproof vapour barrier (ie polyurethane) to prevent damage to the panel.
6 CAVITY PREPARATION IMPORTANT! The power outlet must be located in a cabinet adjacent to the dishwasher cavity. 220-240 VAC min. 4.8 A BENCHTOP 10 mm Moisture protection tape must be applied. Water Connection Recommended COLD (Maximum 60°C). These marks indicate formed bracket screw locations, if securing by drawer removal. 3/4“ BSP (GB20) to suit flat washer. Water Pressure ø 60 mm Water softener models Max. 1 MPa (145 psi) Min. 0.1 MPa (14.
7 PREPARATION FOR EXTERNAL VENTING THROUGH SAME CABINET External Venting Kit (Excludes DD60SLI9 models) Shelf cutouts max. 5mm VENT HOSE Services can be located either side of dishwasher ø 60mm ø 60mm IMPORTANT! To prevent pooling of condensation from the vent hose, a toekick height of no less than 100mm is required. SERVICES 220mm min.
8 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE RIGHT HAND SIDE LEFT HAND SIDE Drain hose - 1800mm Drain hose - 2000mm Inlet hose - 1250 mm Inlet hose - 1650mm Power cord (excl.plug) - 1650mm Power cord (excl.plug) - 1650mm Venting hose - 1525mm 9 Venting hose - 1925mm TALL HEIGHT INTEGRATED MODELS FOR 480 MM CAVITY ONLY - ATTACH CAVITY BRACKET IMPORTANT! The enclosed cavity bracket is fitted before installation in order to conceal the gap at the top of the cavity left after installation.
NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITABLE FOR YOUR CABINETRY... !0 RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) !0-A B ATTACH SIDE MOUNTING BRACKETS Clip all four side mounting brackets into their slots using a flat-bladed screwdriver. Ensure they’re securely fitted before sliding product into cavity.
!2-A PULL THROUGH HOSES & MOVE INTO THE CAVITY !3-A SECURE TO THE CABINETRY ON THE SIDES 1 Open the drawer halfway. Using a flat bladed screwdriver, prise the grey rubber plug out of the trim moulding. Replace the grey rubber plug back into the trim moulding and ensure the trim seal is facing forward. 3 2 Vent hose either through same cabinet or adjacent cabinet as per Step 7b or 7c As you push product in, pull through hoses and cord, ensuring they don’t get kinked or twisted.
!0 !0-A ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVAL !1-A ATTACH VENTING HOSE PULL THROUGH HOSES & MOVE INTO THE CAVITY Check that the fitted elbow is rotated left or right (depending on the direction of the routing), then ensure the venting hose is securely attached to it. Fitted Elbow Vent hose either through same cabinet or adjacent cabinet as per Step 7b or 7c As you push product in, pull through hoses and cord, ensuring they don’t get kinked or twisted.
!2-B !3-B REMOVE THE DRAWER To prevent kinked hoses Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal. 1 SECURE TO THE CABINETRY ON THE SIDES The product has three pairs of fixing points: Ensure the sound insulation is repositioned correctly. 4 Push drawer runners back in on either side.
!4-B REFIT THE DRAWER ONTO THE RUNNERS 2 Lift or rotate anti-clockwise the drawer back onto the drawer runners on either side. Before refitting the drawer, ensure the hoses are not twisted and the latches at the rear of each drawer runner are facing forward. 100 mm 3 Pull the release tabs forward on both sides 100 mm. Ensure the tabs are fully pulled forward and click into place.
!6 !6-A INSTALLING A CUSTOM FRONT DRAWER PANEL REMOVE PANEL BRACKET FROM PRODUCT !6-B REMOVE THE KNOCK-TO-PAUSE MODULE WARNING! Electrical Shock Hazard Before continuing, ensure that the product is disconnected from the power supply. Failure to follow this warning may result in electrical shock, injury or fire. Knock-to-Pause module 1 1 Side Pin 2 1 Remove side pins and gently pull off the panel bracket slightly.
!6 !6-C INSTALLING CUSTOM FRONT DRAWER PANELS !6-D ATTACH CUSTOM PANELS TO PANEL BRACKETS 2 3 ATTACH KNOCK-TO-PAUSE MODULE TO CUSTOM PANEL x6) m( 16m 1 There must be at least 3 screws used each side. Align bottom of each custom panel with the bottom of each bracket. 16mm (x3) 2 IMPORTANT! ● ● Ensure the Knock-To-Pause module is orientated correctly before attaching. Ensure the module is centralized in the holes and not in contact with the bracket.
!6 !6-E INSTALLING CUSTOM FRONT DRAWER PANELS CONNECT THE KNOCK-TO-PAUSE MODULE TO THE CONTROLLER !6-F RECONNECT THE EARTH WIRE TO THE PANEL BRACKET WARNING! Electrical Shock Hazard To earth the panel bracket, connect the earth wire from the product to one of the tabs. Any custom metal component (e.g. handle) that extends past the rubber seal must be earthed too. Failure to follow these warnings may result in electrical shock, injury or fire. Controller Reconnect the Earth Wire to the Panel bracket.
THERE ARE TWO DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE. Dishwasher using drain hose joiner onto sink trap/waste tee Dishwasher and Ø 38 mm Standpipe 2 3 1 step 18 min. 500 mm 38 mm 750 - 882.5 mm 1 step 18 750 - 882.5 mm max. 120 mm min. 500 mm 2 If space is limited for fixing, push hose through drain hose support to required height 750-882.
!8 CONNECT INLET HOSE TO COLD WATER !9 PLUG PRODUCT IN min. 10mm 3/4” BSP connector 180o No leaks! Ensure the supplied rubber washer is fitted inside the coupling. 2 1 Tighten coupling with spanner.
@0 TROUBLESHOOTING ● Excessive water remaining above the filter plate, after the rinse cycle. (This is displayed as an A3 fault. See user guide ‘How to attend to a fault’) Check for a kinked drain hose, blocked or incorrectly drilled out waste connection, highloop not properly installed, drain hose not routed correctly or spray arm not in place. ● No water supply. (This is displayed as an A1 fault. See user guide ‘How to attend to a fault’) Check water is connected and turned on.
@1 FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER Check all parts are installed. Ensure that all panels and parts thereof are secure and final electrical tests have been conducted in accordance with local electrical regulations. Turn on the power and water supplies, then open the drawer. You should hear a beep and see a program indicator light up on the control panel. Check the spray arms are in place, mounted correctly and free to rotate, by physically rotating by hand.