COMPANION PRODUCTS Coffee Maker EB60 Steam Oven OS60 Microwave Oven OM60 models INSTALLATION GUIDE NZ AU GB IE
CONTENTS Coffee maker 13 Steam oven Microwave oven 17 10 1 Safety and warnings 18 9 1 Safety and warnings 1 1 Safety and warnings 2 Parts supplied 2 2 Parts supplied 11 2 Prior to installation 19 3 Prior to installation 3 3 Prior to installation 11 3 After installation 19 4 After installation 3 4 After installation 12 4 Product dimensions 5 Product dimensions 4 5 Product dimensions 13 21 5 6A Cabinetry dimensions (460mm high cavity) 5A Cabinetry dimensions (
COFFEE MAKER EB60 models
1 SAFETY AND WARNINGS IMPORTANT SAFETY INSTRUCTIONS! Installation WARNING! Cut Hazard Take care – some edges are sharp. Failure to use caution could result in injury or cuts. Checking for transport damage After removing the packaging, make sure the product is complete and undamaged and that all accessories are present. Do not use the appliance if it is visibly damaged. Contact Customer Care.
2 PARTS SUPPLIED Screws (28) Lock Hook (1) Rails (2) Clip (1) Spacers (4) for side (4) for bottom 3 PRIOR TO INSTALLATION ● ● ● ● ● ● ● ● ● The countertop and coffee maker cavity are square and level, and are the required dimensions. The installation will comply with all clearance requirements and applicable standards and regulations. The isolating switch will be easily accessible to the customer with the coffee maker installed.
5 PRODUCT DIMENSIONS E H C F D SIDE TOP B I EB60 MODELS PRODUCT DIMENSIONS A Overall height of product A FRONT 458 B Overall width of product 596 C 480 Overall depth of product D Height of chassis 445 E Width of chassis 560 F Depth of chassis 460 G Depth of coffee maker frame and control panel H Stepdown control panel to chassis I Height of control panel 4 | COFFEE MAKER INSTALLATION GUIDE mm 20 13 100
6A CABINETRY DIMENSIONS (460mm HIGH CAVITY) Verify the minimum measurements required for correct installation of the appliance. The coffee maker must be installed in a column and the column must be firmly fixed to the wall with commercially available brackets. IMPORTANT! PROUD INSTALL All installation or maintenance operations must be performed with the appliance disconnected from the mains electricity supply. Kitchen furniture in direct contact with the appliance must be heat resistant 65°C min.
6B CABINETRY DIMENSIONS (480mm CAVITY TRIM KIT) Verify the minimum measurements required for correct installation of the appliance. The coffee maker must be installed in a column and the column must be firmly fixed to the wall with commercially available brackets. IMPORTANT! ● ● ● All installation or maintenance operations must be performed with the appliance disconnected from the mains electricity supply. Kitchen furniture in direct contact with the appliance must be heat resistant 65°C min.
7 INSTALLATION INSTRUCTIONS x 28 x2 x1 2mm 2 mm approx. 350mm (=) (=) 1 Position the rails on the sides of the cabinet. Fix with the screws provided, then extend the rails completely. ● Position and fix the lock hook with the four screws provided, as shown. ● If the coffee maker is installed over a warmer drawer, use the top surface of this as a reference to position the rails. In this case, there will be no surface to rest the rails on. 2 Fix the power cable with the clip.
8 CONNECT THE WARMING DRAWER TO THE MAINS SUPPLY IMPORTANT! ● ● All electrical work may only be carried out by suitably qualified and competent persons in accordance with national and local safety regulations. This warming drawer must be earthed. Before placing the coffee maker into the cavity, route the power cord into the back of the cavity and plug it in to the switched socket. The switched socket should be in an easily accessible area within 900mm of the centre rear of the product.
8 FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER F Make sure the coffee maker is level and securely fitted to the cabinetry. F Check the lower trim is undamaged. F Check there is adequate clearance. This is to ensure correct air circulation. F Make sure any cable ties and internal packaging has been removed from the coffee maker cavity. F Make sure all coffee maker vents and openings are clear and free of any obstruction or damage.
STEAM OVEN OS60 models
1 SAFETY AND WARNINGS IMPORTANT SAFETY INSTRUCTIONS! Installation WARNING! Electrical Shock Hazard Before carrying out any work on the electrical section of the appliance, it must be disconnected from the mains electricity supply. Connection to a good earth wiring system is absolutely essential and mandatory. Alterations to the domestic wiring system must only be made by a qualified electrician Failure to follow this advice may result in electrical shock or death.
2 PRIOR TO INSTALLATION ● ● ● ● ● ● ● ● ● The countertop and oven cavity are square and level, and are the required dimensions. The installation will comply with all clearance requirements and applicable standards and regulations. The isolating switch will be easily accessible to the customer with the oven installed. The electrician provides sufficient free length of power supply cable to reach from the bottom rear of the cavity to at least 1.5m in front of the bottom edge of the opening.
4 PRODUCT DIMENSIONS E C F D G H TOP SIDE B OS60 MODELS PRODUCT DIMENSIONS A A Overall height of product 458 B Overall width of product 596 C 562 Overall depth of product (excluding handle and dials) D Height of chassis 445 E Width of chassis 556 F Depth of chassis 540 G Depth of oven frame and control panel FRONT mm 22 (=distance between front of chassis and front of oven door, excl.
5A CABINETRY DIMENSIONS (460mm HIGH CAVITY) The oven can be installed under a cooktop, in a column. The cabinet material must be able to withstand heat. The oven must be centered within the walls of the cabinet and fixed with the screws and bushings that are provided.
5B CABINETRY DIMENSIONS ● ● ● (480mm CAVITY TRIM KIT) The oven must be installed under a cook top, in a column. The cabinet material must be able to withstand heat. The oven must be centered within the walls of the cabinet and fixed with the screws and bushings that are provided. PROUD INSTALL 16–20mm To install the trim kit, refer to the instructions which accompany it.
6 ELECTRICAL HOOK-UP ● ● Before connecting to the electricity, make sure that the: specifications of the electrical system match with what is detailed on the serial number plate applied to the front of the oven. system has an effective earth connection compliant with current standards and laws. l N The earth connection is required by law. The cable must not, at any point, reach a temperature greater than 50°C above room temperature.
8 FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER F Make sure the oven is level and securely fitted to the cabinetry. F Check the lower trim is undamaged. F Open the (lower) oven door slowly until it is fully open and check there is adequate clearance between the bottom of the door and the lower trim. This is to ensure correct air circulation. Should the lower trim become damaged, straighten the trim and ensure the oven door opens fully without obstruction.
MICROWAVE OVEN OM60 models
1 SAFETY AND WARNINGS IMPORTANT SAFETY INSTRUCTIONS! Installation WARNING! Electrical Shock Hazard Before carrying out any work on the electrical section of the appliance, it must be disconnected from the mains electricity supply. Connection to a good earth wiring system is absolutely essential and mandatory. Alterations to the domestic wiring system must only be made by a qualified electrician Failure to follow this advice may result in electrical shock or death.
2 PRIOR TO INSTALLATION ● ● ● ● ● ● ● ● ● The countertop and oven cavity are square and level, and are the required dimensions. The installation will comply with all clearance requirements and applicable standards and regulations. The isolating switch will be easily accessible to the customer with the oven installed. The electrician provides sufficient free length of power supply cable to reach from the bottom rear of the cavity to at least 1.5m in front of the bottom edge of the opening.
4 PRODUCT DIMENSIONS E C F D G H TOP SIDE B OM60 MODELS PRODUCT DIMENSIONS A mm A Overall height of product 458 B Overall width of product 596 C 562 Overall depth of product (excluding handle and dials) D Height of chassis 445 E Width of chassis 556 F Depth of chassis 540 G Depth of oven frame and control panel FRONT 22 (=distance between front of chassis and front of oven door, excl.
5A CABINETRY DIMENSIONS (460mm HIGH CAVITY) The oven can be installed under a cooktop, in a column The cabinet material must be able to withstand heat. The oven must be centered within the walls of the cabinet and fixed with the screws and bushings that are provided.
5B CABINETRY DIMENSIONS ● ● ● (480mm CAVITY TRIM KIT) The oven must be installed under a cook top, in a column. The cabinet material must be able to withstand heat. The oven must be centered within the walls of the cabinet and fixed with the screws and bushings that are provided. PROUD INSTALL 16–20mm To install the trim kit, refer to the instructions which accompany it.
6 ELECTRICAL HOOK-UP ● ● Before connecting to the electricity, make sure that the: specifications of the electrical system match with what is detailed on the serial number plate applied to the front of the oven. system has an effective earth connection compliant with current standards and laws. l N The earth connection is required by law. The cable must not, at any point, reach a temperature greater than 50°C above room temperature.
8 FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER F Make sure the oven is level and securely fitted to the cabinetry. F Check the lower trim is undamaged. F Open the oven door (lower) slowly until it is fully open and check there is adequate clearance between the bottom of the door and the lower trim. This is to ensure correct air circulation. Should the lower trim become damaged, straighten the trim and ensure the oven door opens fully without obstruction.
FISHERPAYKEL.COM © Fisher & Paykel Appliances 2018. All rights reserved. The product specifications in this booklet apply to the specific products and models described at the date of issue. Under our policy of continuous product improvement, these specifications may change at any time. You should therefore check with your Dealer to ensure this booklet correctly describes the product currently available. NZ AU GB IE 591587B 07.